Oregon Rule and Law Version 2026 Quiz Please sign up for the before taking this quiz. Back Save Progress Retry Finish 1. 160 – Oregon Rule and Law Version 20261Renewable Electrical Energy Bulk Labels may be purchased by ________. A general contractor The property owner only A limited renewable energy contractor only Any licensed electrician 918-309-0410(1) 2. 159 – Oregon Rule and Law Version 20261The misuse and violations of minor installation label rules ________. Are subject to civil penalties Shall result in civil penalties not to exceed 250 dollars Shall result in a license suspension Shall result in a license revocation 918-309-0260 3. 158 – Oregon Rule and Law Version 20261A properly licensed electrical contractor may use a minor label permit for an altered electrical service that does not exceed ________ provided it is not required to be reconnected by the serving utility. 200 amps and 150 volts to ground 200 amps and 250 volts to ground 400 amps and 150 volts to ground 400 amps and 250 volts to ground 918-309-0220(7) 4. 157 – Oregon Rule and Law Version 20261A properly licensed electrical contractor may use a minor label permit for a circuit extension of not more than ________ electrical circuits limited to 30 amps and not more than 300 volts to ground. 1 2 3 4 918-309-0220(7) 5. 156 – Oregon Rule and Law Version 20261A properly licensed electrical contractor may use a minor label permit for a circuit extension of not more than ________ electrical circuits limited to 60 amps and not more than 150 volts to ground. 3 2 1 4 918-309-0220(7) 6. 155 – Oregon Rule and Law Version 20261Generally, a limited energy contractor can use a limited minor electrical permit for a new installation of up to ________ in new construction. 10 devices 15 devices 20 devices 25 devices 918-309-0220(6) 7. 154 – Oregon Rule and Law Version 20261A limited energy contractor can use a limited minor electrical permit for ________. Audio and stereo systems Any vacuum system not over 5 Security systems but only under 5 Fire alarms 918-309-0220(6) 8. 153 – Oregon Rule and Law Version 20261A limited maintenance specialty contractor can take advantage of a minor label electrical permit to replace up to ________ ballasts for light fixtures under one minor permit. 10 15 12 20 918-309-0220(5) 9. 152 – Oregon Rule and Law Version 20261A limited maintenance specialty contractor may use a minor electrical permit label for ________. A garbage disposal up to 20 amperes A dishwasher up to 30 amperes A fan up to 25 amperes A furnace up to 30 amperes 918-309-0220(5) 10. 151 – Oregon Rule and Law Version 20261A limited maintenance specialty HVAC/R contractor may use a minor electrical permit label if the single phase installation does not exceed ________. 150 volts to ground 208 volts to ground 240 volts to ground 250 volts to ground 918-309-0220(5) 11. 150 – Oregon Rule and Law Version 20261A minor electrical permit label may not be used for an installation ________. All of the statements are correct For a swimming pool That requires a plan review That requires a sheet rock cover inspection 918-309-0220(3) 12. 149 – Oregon Rule and Law Version 20261A minor permit label in Oregon is an alternative option for smaller installations instead of a standard electrical permit. A minor label may be used for ________. Burglar or security alarms Any circuit extension Underground electrical installations Hot water heaters 918-309-0220(3) 13. 148 – Oregon Rule and Law Version 20261Records required when a master annual permit is used also include ________. The license number of the person doing the work The materials list used to complete the alteration Any anticipated future projects A one line diagram of the changes 918-309-0100(6) 14. 147 – Oregon Rule and Law Version 20261When an electrical contractor using a master permit for a facility ceases to cover that location, the inspecting jurisdiction shall be notified by the permit holder within ________ of the termination. 10 days 5 days 14 days 30 days 918-309-0100(6) 15. 146 – Oregon Rule and Law Version 20261A covered facility can obtain and use a master electrical permit only if ________. Licensed electricians do the work The facility has used these permits before The facility is over 10 They agree to have progress inspections once a month 918-309-0100(5) 16. 145 – Oregon Rule and Law Version 20261A master electrical permit shall only be provided to ________. All of these can utilize a master permit A facility operating manager A facility owner An electrical contractor 918-309-0100(5) 17. 144 – Oregon Rule and Law Version 20261A master electrical permit covers ________ electrical installations Alterations of Structural retrofits New building shells A small increase in square footage 918-309-0100(4) 18. 143 – Oregon Rule and Law Version 20261A master electrical work permit is used by industrial plants and governmental entities. A master permit is ________. An annual permit Valid for 6 months before expiration Valid for another year after the last inspection Remains active until canceled 918-309-0100(2) 19. 142 – Oregon Rule and Law Version 20261If the rules on temporary electrical work permits are violated, civil penalties may be assessed. The contractor may also be ________ from using these in the future. All of these statements are true. Denied Restricted Suspended 918-309-0080(8) 20. 141 – Oregon Rule and Law Version 20261An inspection for a temporary electrical work permit shall be requested ________. At any time following the permit procedure Within 1 week of completion Within 48 hours of completion Within 24 hours of completion 918-309-0080(6) 21. 140 – Oregon Rule and Law Version 20261When notification to a jurisdiction of the use of a temporary electrical permit is called in, the original with payment must also be mailed in within ________. 7 days 6 days 5 days 4 days 918-309-0080(4) 22. 139 – Oregon Rule and Law Version 20261When notification to a jurisdiction of the use of a temporary electrical permit is faxed in, the original with payment must also be mailed in within ________. 5 days 4 days 3 days 2 days 918-309-0080(4) 23. 138 – Oregon Rule and Law Version 20261A temporary electrical work permit has a starting date, and the ending date shall not be any more than ________ days from the starting date. 7 3 2 10 918-309-0080(4) 24. 137 – Oregon Rule and Law Version 20261A temporary electrical work permit must be signed by ________. The journeyman electrician doing the work The electrical AHJ inspecting the installation A technician only A supervising electrician only 918-309-0080(4) 25. 136 – Oregon Rule and Law Version 20261When using a temporary permit, the contractor must also fill out a standard form electrical permit application ________. Prior to commencing the work After the work is completed Within 48 hours of commencing the work Within 24 hours of commencing the work 918-309-0080(4) 26. 135 – Oregon Rule and Law Version 20261Temporary electrical work permits can be used for ________. Unanticipated electrical work Any provisional work in hazardous locations only And by homeowners Small installations so that no electrical permit is needed also 918-309-0075(2) 27. 134 – Oregon Rule and Law Version 20261When it comes to a temporary electrical work permit, emergency electrical work is considered unplanned electrical repairs or replacements involving ________. An existing electrical installation An existing residential application only An existing commercial application only A new installation 918-309-0075(2) 28. 133 – Oregon Rule and Law Version 20261The Oregon Electrical Specialty Code allows ________ to purchase and use temporary electrical work permits. Licensed electrical contractors only General contractors for construction temporaries Any supervisor electrician Any technician 918-309-0080(1) 29. 132 – Oregon Rule and Law Version 20261A stop-work order may only be issued for ________ violations of the minimum electrical safety standards. Permitted projects for Commercial only for Major Homeowner projects for 918-309-0075(2) 30. 131 – Oregon Rule and Law Version 20261Any person that commences and starts the electrical work before an electrical work permit is issued will be subject to ________. An investigative fee A license revocation A criminal fine A civil penalty 918-309-0070(12) 31. 130 – Oregon Rule and Law Version 20261Bulk electrical permit labels are sold ________ at $25.00 per label Only to electrical contractors To anyone needing a permit To homeowners and low voltage electrical contractors Only to homeowners 918-309-0040(9) 32. 129 – Oregon Rule and Law Version 20261When an electrical service was disconnected for repairs, if a major violation of the service exists, ________. A new service and permit fee is required The corrections shall be completed with 30 days A citation shall be issued to the owner A citation shall be issued to the electrical contractor 918-309-0040(9) 33. 128 – Oregon Rule and Law Version 20261The electrical work permit fee for a manufactured dwelling unit (mobile home) ________. Is typically based on a service and feeder fee Is based on square footage Has a discount available for senior citizens Has a discount available for multiple units 918-309-0030(5) 34. 127 – Oregon Rule and Law Version 20261To calculate the fee for an electrical work permit for a one-family dwelling, ________. You must include the square footage of the garage if it is attached The attached garage is not included in this footprint A discount is available for senior citizens The Specialty Code does not clarify fees regarding garages 918-309-0030(5) 35. 126 – Oregon Rule and Law Version 20261When an electrical work permit is purchased for a two family dwelling unit, the permit purchaser is entitled to _________ inspections. 8 9 10 12 918-309-0025(1) 36. 125 – Oregon Rule and Law Version 20261When an electrical work permit is purchased for a one-family dwelling, the permit purchaser is entitled to ________ inspections. 4 5 6 8 918-309-0025(1) 37. 124 – Oregon Rule and Law Version 20261If an electrical contractor begins the electrical installation before a required plan review is completed ________. The permit purchaser proceeds at his or her own risk The license may be suspended There will be a fine assessed There will be a citation assessed 918-309-0025(1) 38. 123 – Oregon Rule and Law Version 20261When an electrical contractor has a job that requires a state plan review process, _________. A partial permit may be purchased so work can begin An outside firm can be hired to complete the review They can only begin with express consent from the chief They can not begin any work until the process is completed 918-309-0025(1) 39. 122 – Oregon Rule and Law Version 20261When an electrical permit is purchased, the permit purchaser is entitled to at least _________. 2 inspections 1 in person and 1 electronic inspection only 3 electronic inspections 3 in person inspections 918-309-000(11) 40. 121 – Oregon Rule and Law Version 20261The Oregon Electrical Specialty Code does not require an electrical permit for ________. A 30 ampere single phase dishwasher A 50 ampere electric water heater Any appliance Any garbage disposal 918-309-000(10) 41. 120 – Oregon Rule and Law Version 20261The Oregon Electrical Specialty Code does not require an electrical work permit for ________. Some minor electrical installations that can use a minor installation label Homeowners C.O.P. locations Any low voltage applications 918-309-000(10) 42. 119 – Oregon Rule and Law Version 20261The Oregon Electrical Specialty Code does not require any type of an electrical work permit for Replacing fuses Changing luminaire ballasts Changing luminaire drivers Replacing receptacles and switches 918-309-000(10) 43. 118 – Oregon Rule and Law Version 20261When corrections have been issued to a permitted electrical installation, those corrections must be completed within ________ of the notification. 20 days 15 days 30 days 60 days with extensions 918-309-000(8) 44. 117 – Oregon Rule and Law Version 20261Electrical work permits issued under the Oregon Specialty Code become null and void if the electrical work has been suspended or abandoned for a period of _________. 180 days 120 days 60 days 365 days 918-309-000(7) 45. 116 – Oregon Rule and Law Version 20261Electrical work permits issued under the Oregon Specialty Code become null and void if the electrical work is not started within ________. 180 days 120 days 60 days 365 days 918-309-000(7) 46. 115 – Oregon Rule and Law Version 20261An unexpired permit holder ________ for an extension of time within which work may be completed. May apply Of a residential project only may apply Of a commercial project only may apply May not apply 918-309-000(6) 47. 114 – Oregon Rule and Law Version 20261As a general rule, an electrical permit issued to one firm is ________ . Not transferable Transferable only on commercial projects Transferable when one firm does the branch circuits and the other does the service Transferable to another if the first has filed for bankruptcy 918-309-000(5) 48. 113 – Oregon Rule and Law Version 20261An electrical work permit shall be posted ________. In a conspicuous place near the panel or on the job site Near the main electrical panel In the electrical room On the main electrical panel 918-309-000(4) 49. 112 – Oregon Rule and Law Version 20261In the State of Oregon, an electrical work permit is required ________. Prior to the start of the electrical work Before an inspection request Within 1 day of the start of the work Before the plan review process 918-309-000(3) 50. 111 – Oregon Rule and Law Version 20261When purchasing an electrical permit for the State of Oregon, the signature of ________ is required on each permit. A signing supervising electrician The site owner The building owner The electrical contractor 918-309-000(1) 51. 110 – Oregon Rule and Law Version 20261Along with the NEC requirement in article 800 section 800.48 the point of entrance for unlisted non conductive optical fiber cable shall be permitted to be extended by Continuously enclosing the cable in rigid pol vinyl chloride conduit, electrical metallic tubing or __________ Electrical non-metallic conduit ENT Recommend additional measures against cyber attacks Require the results to be sent and filed with the State Require a digital backup Table 1-E 800.48 52. 109 – Oregon Rule and Law Version 20261Feeder taps for Interconnected Electric Power Production Sources (Multiple sources operating in parallel with the primary electric source.) shall not be less that one-third the overcurrent device plus the ratings of any others connected. The State of Oregon Rules ________. Refers you to Statewide Code Interpretation 21-03 Requires express consent from the AHJ Only allows this under the supervision of an engineer Do not allow this Table 1-E 705.12(A) 53. 108 – Oregon Rule and Law Version 20261The 2026 NEC requires Commissioning of energy storage systems upon installation in accordance with the manufacturers instructions. Oregon rule and law has _________ Not adopted this requirement Requires plan review Requires public school Committee input hospital Grade Documentation of the commissioning Table 1-E 706.7 54. 107 – Oregon Rule and Law Version 20261Ground-Fault Circuit-Interrupter Protection (GFCI) for personnel was modified in the NEC to cover all receptacles for electric hand tools or portable lighting in work areas for welders. The Oregon amendments ________. Did not adopt this code section Requires GFCI protection for both 120 volt and 250 volt receptacles Only require GFCI protection for 250 volt receptacles Only require GFCI protection for 120 volt receptacles Table 1-E 630.8 55. 106 – Oregon Rule and Law Version 20261Ground-Fault Circuit-Interrupter Protection (GFCI) for personnel was modified in the NEC to cover all receptacles for electric vehicle charging locations. The Oregon amendments Did not adopt this code section Requires GFCI protection for both 120 volt and 250 volt receptacles Only require GFCI protection for 250 volt receptacles Only require GFCI protection for 120 volt receptacles Table 1-E 625.54 56. 105 – Oregon Rule and Law Version 20261The NEC does not allow reconditioned luminaires, ballasts, and LED drivers. The State of Oregon further clarifies that ________. Maintenance of luminaires is not considered reconditioning Maintenance of luminaires is considered reconditioning Servicing of luminaires is considered reconditioning Trouble shooting of luminaires is considered reconditioning Table 1-E 410.3 B 57. 104 – Oregon Rule and Law Version 20261An electrical Oregon Rule and Law states that panelboards with overcurrent protection should not be greater than the panel board . Individual protection shall not be required for Panel boards usesd as service equipment with multiple disconnecting means in accordance with __________ Article 230.71 Article 250 Article 408 article110 Table 1-E 408.36 58. 103 – Oregon Rule and Law Version 20261A new general rules does not allow receptacle outlets within 3 feet of a dwelling unit bathtub or shower. A modified exception for a small bathroom in Oregon allows the receptacle to be installed ________. Outside the room To be eliminated On the farthest wall within the room Next to the toilet Table 1-E , 406.9 C 1 59. 102 – Oregon Rule and Law Version 20261A modification to the NEC rules that require all receptacles to be rated as suitable for damp locations in Oregon applies to ________. All 125 volt nonlocking receptacles All 125 and 250 volt nonlocking receptacles All 125 through 277 volt nonlocking receptacles All 123 through 480 volt nonlocking receptacles Table 1-E 406.9(A) 1 c 60. 101 – Oregon Rule and Law Version 20261The Oregon State Electrical Specialty Code amendments Section 362.30 securing and supporting ENT to allow __________. Using cable ties that are not listed Installation in accordance with Standard NFPA13 In commercial applications only when identified at the source panelboard Table 1-E , 362.30 A 61. 100 – Oregon Rule and Law Version 20261The Oregon State Electrical Specialty amendments allow overcurrent protective devices in ________. Locker rooms Hotel guest room bathroom Dormitory unit bathrooms Dwelling unit bathrooms Table 1-E , 240.24(E) 62. 099 – Oregon Rule and Law Version 20261The NEC has begun to address remotely adjusting Adjustable-Trip Circuit Breakers via the internet. In Oregon the permit holder ________ demonstrate compliance with this requirement. Is not required to Shall not Is recommended to Is require to Table 1-E 240.6(D) 63. 098 – Oregon Rule and Law Version 20261The NEC additionally required barriers to cover the exposed energized bussing for service panelboards. The State of Oregon rules ________. Added an exception to service equipment with more than 1 disconnect in an enclosure Did not adopt these changes Additionally required a warning label Only recommended this requirement Table 1-E , 230.62(C) 64. 097 – Oregon Rule and Law Version 20261The NEC allows service-entrance conductors to be spiced and tapped. Power distribution blocks and pressure connectors are required by the Oregon Rules to be ________. Listed Marked suitable for service Marked suitable for use on the line side Rated for a minimum of 60K IC Table 1-E 230.46 65. 096 – Oregon Rule and Law Version 20261Emergency disconnects located outside of a dwelling unit were required to aid the first responders. The Oregon amendments ________. Did not adopt this NEC section Only requires this for senior living areas Only requires this in commercial applications Requires access into the disconnecting means for the first responders Table 1-E 230.41 66. 095 – Oregon Rule and Law Version 20261Additional surge protection for feeders was a major change in the NEC. The State of Oregon ________. Does not require this Only requires this for dormitory units Only requires this for guest rooms in a hotel Only requires this for dwelling units Table 1-E 215.18 67. 094 – Oregon Rule and Law Version 20261The 2026 NEC required that where the distribution equipment supplied by the feeder is replaced all of the requirements of 215.18 shall apply. The State of Oregon Rules ________. Do not require this change Clarify that this is only a recommendation Additionally requires posting labels at the panelboard Does not now allow these low voltage switches Table 1-E 215.18(D) 68. 093 – Oregon Rule and Law Version 20261The NEC additionally required barriers to cover the exposed energized bussing for feeder panelboards. The Oregon Electrical Specialty Codes ________. added If supplied by the equipment manufacturer Additionally requires warning labels Additionally requires taping the terminals Only recommends this requirement Table 1-E 215.15 69. 092 – Oregon Rule and Law Version 20261The Oregon State rules also modified the NEC arc fault requirements for dormitory unit receptacles by additionally adding ________ areas. Study Outside Lobbies Parking Table 1-E , 210.12(C) 70. 091 – Oregon Rule and Law Version 20261The Oregon State rules modified the NEC arc fault requirements for dormitory unit receptacles ________ areas. Similar room Living Rooms Closets Hallways Table 1-E , 210.12(C) 71. 090 – Oregon Rule and Law Version 20261The NEC expanded the requirements for GFCI protection for appliances, the Oregon Specialty Code clarified GFCI protection for _________. Specific appliances 3 phase appliances only Single phase appliances only No appliances Table 1-E 210.8(D) 72. 089 – Oregon Rule and Law Version 20261The NEC added additional GFCI protection requirements for aquariums and bait wells. The Oregon rules modified with an exception if the device is installed ________ and a single receptacle is installed. Indoors Outdoors Above 5 feet Above 6 feet Table 1-E , 210.8(B)ex 7 73. 088 – Oregon Rule and Law Version 20261The NEC defines a kitchen which includes an area with sinks and permanent provisions for food preparation. Th Oregon State rules Did not adopt this definition Expanded the definitions to outside wet bars Expanded the definition to include beverage preparation Have adopted the 2023 NEC definition Table 1-E , 210.8 A 74. 087 – Oregon Rule and Law Version 20261The NEC clarified the general rules regarding identification of disconnecting means. Oregon additionally noted that the location of the circuit source information should include ________. A circuit number A room number An electrical room number Any description Table 1-E 110.22(A) 75. 086 – Oregon Rule and Law Version 20261A new alterative method from the NEC to recondition and restore electrical equipment in Oregon is to use replacement parts ________. Selected by the supervising electrician Designed by any engineer By the manufacturer only Selected by the electrical inspector Table 1-E 110.20 76. 085 – Oregon Rule and Law Version 20261NEC addressed servicing and preventive maintenance with used electrical equipment adding requirements. In Oregon ________. Repairs are permitted without additional requirements It shall be approved by the AHJ prior to the work The repairs shall be designed by an electrical engineer Only testing is approved Table 1-E 110.17 77. 084 – Oregon Rule and Law Version 20261A change has now begun to address cybersecurity for network-connected life safety equipment. In Oregon the permit holder ________ demonstrate compliance with this requirement for this type of installation. Is not required to Shall not Is recommended to Is required to Table 1-E , 110.3(A)(8) 78. 083 – Oregon Rule and Law Version 20261A change in the definition of servicing in the Oregon rules now includes the ________ of used equipment with listed or recognized components. (Also can be a factor when it comes to licensing compliance.) All of these items are now included Repair Testing Inspection Table 1-E 100 Definitions 79. 082 – Oregon Rule and Law Version 20261A new clarification of the NEC definition of a structure in Oregon now includes ________. (Important when it comes to floating a neutral or not.) A post with an attached meter base An electric pump station A branch circuit to a furnace Any light standard Table 1-E 100 Definitions 80. 081 – Oregon Rule and Law Version 20261There now includes a clarification for the electrical datum plane (elevation) calculations for locations such as marinas. The electrical datum plane shall be determined in accordance with __________ codes. The Oregon Structural or Residential codes An electrical supervisor Each county jurisdiction The NEC 2020 edition Table 1-E 90.4(D) 81. 080 – Oregon Rule and Law Version 20261An example of a condition requirement for product use in a system that generates and distributes electricity that is not certified includes the ________. System being designed by an engineer Owner not being a wholesale generator System is not connected to a utility grid Turbines are 10KW 918-261-0030 82. 079 – Oregon Rule and Law Version 20261An example of the exemption for underground electrical transmission lines from permits and licensing is when the equipment is owned and operated by ________. A municipality A hospital A county A school 918-261-0030 83. 078 – Oregon Rule and Law Version 20261An example of the exemption for an underground signal loop from inspections would be a Class 2 ________. Traffic signal device Audio system CCTV system Security system 918-261-0025 84. 077 – Oregon Rule and Law Version 20261There is an exemption from permits for the repair or replacement of an HVAC ________. Capacitor Flex whip Disconnect Branch Circuit 918-261-0020 85. 076 – Oregon Rule and Law Version 20261A general journey-level can be exempt from the engineering requirements for the designing of a fire protection system. When he/she qualifies, he/she is not subject to any requirements for additional ________. Permits Certification stamps Training Installation requirements 918-261-0015 (2) 86. 075 – Oregon Rule and Law Version 20261In regards to the Oregon Administrative Rules, a Signing Supervising Electrician is authorized by the electrical contractor to sign ________. Permits Contracts Payroll checks Bids 918-251-0090 87. 074 – Oregon Rule and Law Version 20261A Plug-in Replacement does not have ________ that is connected to the plug-in part or assembly. Any field wiring Any hard wiring Any software Any mechanical hardware 918-251-0090 88. 073 – Oregon Rule and Law Version 20261A Listed Product means a product that was examined and accepted by ________. An NRTL UL only ETL only CSA or ETL only 918-251-0090 89. 072 – Oregon Rule and Law Version 20261A Limited Energy System can mean a system that includes ________. All of these statements are true. An audio system A power limited fire alarm A communication system 918-251-0090 90. 071 – Oregon Rule and Law Version 20261When an electrical item is Labeled, it will have an identifying mark by ________. An NRTL UL only CSA or UL only ETL only 918-251-0090 91. 070 – Oregon Rule and Law Version 20261In Oregon, a Jurisdictional Inspector can be a ________. State or municipal inspector Municipal inspector only State inspector only County inspector only 918-251-0090 92. 069 – Oregon Rule and Law Version 20261For the purposes of electrical licensing, an Industrial Plant can include a ________. All of these statements are true. Sewer Plant Hospital School 918-251-0090 93. 068 – Oregon Rule and Law Version 20261An Indorsement determines the ________ of work authorized under a restricted electrical license. Scope Limitation Restriction Activity 918-251-0090 94. 067 – Oregon Rule and Law Version 20261An electrical Engineer in Oregon is an individual who has completed a minimum ________ in electrical engineering or technology. 4 year program High voltage program NEC degree 2 year program 918-251-0090 95. 066 – Oregon Rule and Law Version 20261In Oregon, the Electrical Specialty Code means ________. The NEC with Oregon amendments The Oregon Rules only The NEC and the NESC The NEC 918-251-0090 96. 065 – Oregon Rule and Law Version 20261When something is Custom Made, it is an electrical product that Is designed for a specific purpose Has only 1 use Is designed for multiple locations Is made at an industrial plant 918-251-0090 97. 064 – Oregon Rule and Law Version 20261When an electrical contractor has a person that is Continuously Employed, he or she devotes ________ of employment to the tasks such as supervising. Their entire time 0.5 0.25 0.75 918-251-0090 98. 063 – Oregon Rule and Law Version 20261The definition of a Building, electrically speaking, can be when it is isolated from an adjoining structure by Separation walls Labeling 1 hour fire doors only Certification marking 918-251-0090 99. 062 – Oregon Rule and Law Version 20261The definition of Appliance, in regards to the limited maintenance specialty contractor license, does not include Generally Deep frying equipment Clothes washing equipment Food mixing equipment 918-251-0090 100. 061 – Oregon Rule and Law Version 20261The definition of Approved, in regards to a product, means Approved by the Electrical Board Only approval by the department A consensus Stakeholder approval 918-251-0090 101. 060 – Oregon Rule and Law Version 20261 According to Oregon Rule & Law (Table 1-E), when a building or structure is supported by a PV system, the PV equipment grounding conductor must be connected to the grounding electrode system in accordance with Article 250. What is the minimum permitted size of the grounding electrode conductor? Sized per 250.66 and not smaller than No. 6 copper or No. 4 aluminum Not smaller than No. 8 copper or No. 6 aluminum Sized per 250.122 and not smaller than No. 10 copper Sized per 690.45 and not smaller than No. 8 aluminum Table 1-E , 690.47 A 102. 059 – Oregon Rule and Law Version 20261 According to Oregon Rule & Law (Table 1‑E), exposed single conductors shall be supported and secured by which of the following methods? Cable ties Only listed cable ties Conduit clamps installed at intervals not exceeding 24 inches Only rigid PVC supports listed for outdoor use Table 1-E, 690.31 (C)(1) 103. 058 – Oregon Rule and Law Version 20261For a swimming pool, ________ shall be permitted to required periodic inspections and/or testing. The State of Oregon did not adopt this. The Chief Electrical Inspector The State of Oregon The Authority Having Jurisdiction Table 1-E 680.4 104. 057 – Oregon Rule and Law Version 20261In an elevator pit, sump pumps are required to be protected with Class A GFCI protection for personnel, unless ________. It is a single receptacle and labeled It is single-phase It is 3-phase There is also qualified personnel on site Table 1-E , 620.7 A 105. 056 – Oregon Rule and Law Version 20261 For solidly grounded wye electrical services operating at more than 150 volts to ground but not exceeding 1000 volts phase‑to‑phase, where the available fault current exceeds 10,000 amperes, the NEC requires the service overcurrent protective devices to be a Current limiting overcurrent protective device. Oregon rule in law table1 – E has _ Not adopted by the state of Oregon Required to be examined by a licensed individual Required to be maintained by a qualified person Required to be tested monthly Table 1-E 590.9 B 106. 055 – Oregon Rule and Law Version 20261When ground fault protection of equipment (GFPE) Is coordinated and performance testing is required a____________ having proper training and experience required to perform and evaluate the result of such performance testing will be used according to the manufacturers instructions person(s) Qualified AHJ Specialist Table 1-E , 555.35(F) 107. 054 – Oregon Rule and Law Version 20261In a place of assembly, illumination shall be required for working spaces around outdoor None of these statements are true. Switchgear Service equipment only Motor control centers Table 1-E 518.8 108. 053 – Oregon Rule and Law Version 20261Ground-fault protection performance testing in a Health Care Facility shall be conducted by A person with proper training to evaluate the results A qualified person The manufacturer only A licensed journey-level electrician Table 1-E 517.17(D) 109. 052 – Oregon Rule and Law Version 20261Part II of NEC Article 517 shall not apply to ________ areas. All of these statements are true. Audiology Physical therapy Message therapy Table 1-E , 517.10(B) 110. 051 – Oregon Rule and Law Version 20261If electrical switchgear has been damaged by fire or water, it shall be evaluated by ________ prior to being returned to service The signing supervisor A licensed journey-level electrician A qualified testing laboratory only The manufacturer only Table 1-E , 495.3 A 111. 050 – Oregon Rule and Law Version 20261Personnel doors intended for egress from designated battery rooms shall be equipped with Panic or fire exit hardware Listed panic hardware Listed fire exit hardware Instructions posted on the door Table 1-E , 480.10(E) 112. 049 – Oregon Rule and Law Version 20261 Emergency shutdown in one and two family dwelling units for other than cord and plug connected portable generators an emergency shutdown device shall ________ Now all of these are required in Oregon Shall meet the requirements of 445.19(A)(1) Shall be located outside Shall be accessible Table 1-E , 445.19(C) 113. 048 – Oregon Rule and Law Version 20261 Oregon Rule & Law added a new exception to 440.14 for ductless mini‑split HVAC systems. Under this exception, the lockable disconnecting means located at the outdoor equipment may serve as the disconnecting means for the indoor unit when which condition is met? The outdoor equipment is designed to supply both the power and the control wiring to the indoor equipment The outdoor unit is listed as “multi‑zone capable” and the indoor unit is within sight The indoor unit is less than 1 horsepower and the disconnect is grouped with other HVAC equipment Need to be specifically approved by a supervisor Table 1-E , 445.14 ex.3 114. 047 – Oregon Rule and Law Version 20261 Sump and sewage pumps are generally required to be protected with Class A GFCI protection for personnel, unless It is a single receptacle and labeled not GFCI protected It is 3-phase It is single-phase The outdoor disconnect is mounted no higher than 6 ft 7 in. above grade and is field-labeled by the AHJ Table 1-E , 422.5(A)(6) 115. 046 – Oregon Rule and Law Version 20261If electrical equipment has been damaged by fire or water, it shall be evaluated by _______ prior to being returned to service. The signing supervisor A licensed journey-level electrician A qualified testing laboratory only The manufacturer only Table 1-E , 408.3 A 116. 045 – Oregon Rule and Law Version 20261In the State of Oregon, all 15 and 20 ampere, 125 volt, nonlocking type receptacles in _________ shall be listed as tamper-resistant receptacles Mobile homes Outdoor locations All locations Business offices Table 1-E 406.26 117. 044 – Oregon Rule and Law Version 20261Receptacles shall not be installed within or above a bathtub, Or shower stall Or steam room Nor within 12 feet vertically Nor within 5 feet horizontally Table 1-E , 406.9 C 1 118. 043 – Oregon Rule and Law Version 20261Type MC cable ________ secured and supported by cable ties May be Can be (if they are listed only) Can be (if they are identified only) Shall not be Table 1-E , 330.30 A 119. 042 – Oregon Rule and Law Version 20261An interior of a raceway installed in a wet location shall also be considered a wet location, unless _____ It is installed solely for physical protection It is installed inside a building It is installed above grade The raceway is 20 feet or less in length Table 1-E , 300.9 ex 120. 041 – Oregon Rule and Law Version 20261Conduits or raceways through which moisture may contact live parts shall be sealed At either or both ends At one end only At both ends With identified listed sealant for use Table 1-E, 300.7 G 121. 040 – Oregon Rule and Law Version 20261 NEC 230.70 requires an emergency disconnect for one‑ and two‑family dwellings. According to Oregon Rule & Law, this requirement is: Not adopted by the state of Oregon Adopted with Oregon-specific exceptions Adopted without changes Required only for new construction Table 1-E , 230.70 A 122. 039 – Oregon Rule and Law Version 20261NEC 230.67 normally requires a surge protective device (SPD) on all dwelling unit services. According to Oregon Rule & Law, this section is ________. Not adopted by the state of Oregon Industrial applications only Commercial structures only Dwelling units Shall be provided Table 1-E 230.67 123. 038 – Oregon Rule and Law Version 20261Each meeting room of not more than 1,000 square feet Has not been adopted by the state of Oregon Shall have receptacle outlets in accordance with NEC 210.65 Shall have at least 1 floor receptacle at least 6 feet from the wall Receptacle outlets at 48 inches to the top of box only Table 1-E 210.65 124. 037 – Oregon Rule and Law Version 20261A deck or porch that is located above grade is required to have at least 1 receptacle outlet installed, unless It has a depth of 1 foot or less It has a depth of 2 feet or less It has an area of less than 25 square feet It has an area of less than 30 square feet Table 1-E , 210.52(E)(3) 125. 036 – Oregon Rule and Law Version 20261According to the NEC 210.52(C)(2) as adopted by Oregon Rule & Law, which statement is TRUE regarding receptacle outlets on kitchen island or peninsula countertops in dwelling units? A receptacle outlet is not required At least one receptacle outlet is required on every island or peninsula. One minimum at each end At least 1 for the first 9 square feet Table 1-E, 210.52 (C)(2) 126. 035 – Oregon Rule and Law Version 20261In a dormitory unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in Bathrooms Closets Hallways Living rooms Table 1-E , 210.12(C) 127. 034 – Oregon Rule and Law Version 20261In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in An area that serves an appliance that is fastened in place A pet wash location An area that could be considered a damp location that can cause unwanted tripping In any wet location Table 1-E , 210.12(B)ex 4 128. 033 – Oregon Rule and Law Version 20261In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in Locations with dedicated outlets that supply equipment known to cause unwanted tripping All of these statements are true Sunrooms with GFCI protection Living rooms with dedicated circuits Table 1-E , 210.12(B)ex 3 129. 032 – Oregon Rule and Law Version 20261In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in All of these statements are true. Hallways Laundry areas Kitchens Table 1-E , 210.12(B)ex 2 130. 031 – Oregon Rule and Law Version 20261Generally, all outdoor ________ for other than dwelling units, that are supplied by single-phase branch circuits rated 150 volts to ground or less (60 amperes or less) shall have GFCI protection General purpose receptacles Outlets up to 8 feet above grade Outlets Dedicated circuits Table 1-E , 210.8(F) 131. 030 – Oregon Rule and Law Version 20261A 125 volt, 20 ampere receptacle, installed inside a dwelling unit to service heating and air conditioning equipment is Not required to be GFCI protected unless required otherwise in the code Required to be GFCI protected Required to be installed within 60 feet of the unit Required to be installed with AFCI protection Table 1-E , 210.8(E) 132. 029 – Oregon Rule and Law Version 20261GFCI protection shall not be required for a single receptacle serving an appliance if All of these statements are requirements The appliance is located within a dedicated space The appliance is not easily moved or fastened in place The receptacle is labeled as not GFCI protected Table 1-E , 210.8 A 133. 028 – Oregon Rule and Law Version 20261In the State of Oregon, all ________ 15 and 20 ampere receptacles installed in other than dwelling unit locations specified in 210.8(B)1-12, shall have GFCI protection for personnel 125 volt single phase only 125 volt single phase through 208 volt 125 volt single phase through 250 volt 250 volt single phase Table 1-E , 210.8(B) 134. 027 – Oregon Rule and Law Version 20261Indoor damp and wet locations of dwelling units are ________ GFCI protection for 125 volt, 15 and 20 ampere receptacles. Are no longer mentioned in the ORLs Now recommended to have Suggested to install Required to have (starting 1/1/25) Table 1-E , 210.8 A 135. 026 – Oregon Rule and Law Version 20261In Oregon State, ________ in a dwelling unit are not required to have GFCI protection for all 125 volt, single phase, 15-20 ampere receptacles Kitchen receptacles that do not serve the countertop Laundry areas Garages Outdoors Table 1-E , 210.8(A)(7) 136. 025 – Oregon Rule and Law Version 20261In the State of Oregon, all ________ 15 and 20 ampere receptacles installed in dwelling unit locations specified in 210.8(A)1-10 shall have GFCI protection for personnel. 125 volt single phase only 125 volt single phase through 208 volt 125 volt single phase through 250 volt 250 volt single phase Table 1-E , 210.8 A 137. 024 – Oregon Rule and Law Version 20261When doors are required to be equipped with panic hardware, the panic hardware for quick egress shall be ________. Listed in accordance with UL 305 Labeled Tested Tested monthly with the records kept Table 1-E, 110.26 (C)(3) 138. 023 – Oregon Rule and Law Version 20261An Alcove in the Oregon Specialty Electrical Code is additionally defined as an area with a ________. Depth of not less than 2 feet Depth of not less than 3 feet Length of not less than 4 feet Length of not less than 5 feet Table 1-E, 100 139. 022 – Oregon Rule and Law Version 20261A dormitory in Oregon is considered a space in a building where group sleeping accommodations are provided in one or more closely associated rooms with up to _________ persons There is no designated count 12 16 10 Table 1-E, 100 140. 021 – Oregon Rule and Law Version 20261Requests for special permission to waive specific requirements in Oregon shall be in writing and shall be obtained Prior to the start of the electrical work Within 1 week of the start of the electrical work With a 250 dollar fee AAnd considered and determined within 1 week Table 1-E , 90.4(C) 141. 020 – Oregon Rule and Law Version 20261Existing electrical installations in Oregon that complied with previous National Electrical Code standards Are considered presently in violation of current codes if the use of the building is changed Are considered presently in violation of current codes May be considered in violation of current codes in all cases Will never be considered in violation of current codes 918-305-0000 142. 019 – Oregon Rule and Law Version 20261A general journey-level electrical 8,000 hour apprenticeship program in Oregon with at least ________ hours of on-the-job training may work under indirect supervision. 6500 6000 5000 7000 918-282-0270 143. 018 – Oregon Rule and Law Version 20261To become a general journey-level electrical apprentice in Oregon, All of these statements are true. You must have had some mathematics with a grade of C or better You must have a high school diploma You must be 17 years of age to apply 918-282-0270 144. 017 – Oregon Rule and Law Version 20261A licensed limited stage electrician journey-level Can maintain temporary equipment used during a show when it is designed to be accessed by qualified personnel Can install permanent wiring at a performance venue Cannot work on film or video productions Does not have to be employed by an electrical contractor when working 918-282-0230 145. 016 – Oregon Rule and Law Version 20261A licensed journey-level limited sign electrician is not permitted to Perform work on service equipment Install outline lighting Extend any sign circuit Install electrical signs 918-282-0220 146. 015 – Oregon Rule and Law Version 20261A licensed journey-level limited sign electrician may extend an existing dedicated sign branch circuit not more than ________ 15 feet 25 feet 10 feet 918-282-0220 147. 014 – Oregon Rule and Law Version 20261A licensed limited manufacturing plant journey-level ________ electrical products in an industrial plant owned by the licensees employer All of these statements are true. Can install Can maintain Can replace and repair 918-282-0190 148. 013 – Oregon Rule and Law Version 20261A licensed limited residential electrician can make electrical installations on multi-family dwelling units when not exceeding ________ floors above grade 3 10 4 2 918-282-0180 149. 012 – Oregon Rule and Law Version 20261A licensed general journey-level electrician is authorized to do ________. Any electrical installation Residential electrical installations only General electrical installations only Commercial electrical installations only 918-282-0170 150. 011 – Oregon Rule and Law Version 20261A limited supervising electrician may direct an electrical installation in an existing _________. Hospital Duplex Dwelling Unit Multifamily structure 918-282-0160 151. 010 – Oregon Rule and Law Version 20261The general signing supervising electrician shall ________ Sign all permits Pay for all permits Fill out all permits Process all permits 918-282-0140 152. 009 – Oregon Rule and Law Version 20261________ is the only individual authorized to supervise the installation or alteration of an electrical service A general supervising electrician A general electrician A journey-level electrician The owner 918-282-0140 153. 008 – Oregon Rule and Law Version 20261When a general supervising electrician is working for an electrical contractor, he/she may design, plan, and lay out work for ________. The customers of the contractor he/she is working for Any installation within his/her electrical scope Any installation if he/she is an engineer Only for altered electrical services 918-282-0140 154. 007 – Oregon Rule and Law Version 20261An owner of a facility having electrical employees ________ to the division the names and license numbers of limited supervising or limited maintenance electricians employed. Shall report in writing Shall report in writing twice a year Does not have to report Can report 918-282-0120 155. 006 – Oregon Rule and Law Version 20261Electrical licenses in Oregon are not required to install limited energy systems not exceeding ________ in Class 2 systems within a given list of items. 100 VA 24 VA 120 VA 500 VA 918-282-0110 156. 005 – Oregon Rule and Law Version 20261Electrical licenses in Oregon are not required to do testing of electrical products in _________. All of these statements are true. A recognized UL testing lab Industrial plants An electrical shop 918-282-0110 157. 004 – Oregon Rule and Law Version 20261A registered signing supervising electrician shall provide direct supervision or control on a job by ________. All of these statements are true. Being on the job site Having a continuously employed full time supervising electrician on the job site Be available in person to meet with the inspector on the job site within 2 business days 918-282-0015 158. 003 – Oregon Rule and Law Version 20261Return of the minor label log sheet to the division or proper jurisdiction shall be: when all the labels in the lot are used, or ________ from the date of sale; whichever occurs first 12 months 6 months 9 months 90 day 918-100-0050 159. 002 – Oregon Rule and Law Version 20261Minor labels sold by the division for electrical installations shall be sold ___________. In lots of 10 In lots of 20 In lots of 50 One at a time 918-100-0030 160. 001 – Oregon Rule and Law Version 20261An electrical minor label is chosen to permit a small job. When must you post the label on the job site? Before the work begins After the work is completed Within 10 calendar days of completion Before or while the work is in progress 918-100-0050 Back Save Progress Retry Finish