Oregon Rule and Law Version 2023 Quiz Please sign up for the before taking this quiz. Back Save Progress Retry Finish 1. 115 – Oregon Rule and Law Version 20231An unexpired permit holder ________ for an extension of time within which work may be completed. May apply Of a residential project only may apply Of a commercial project only may apply May not apply Reference : 918-309-000(6) 2. 150 – Oregon Rule and Law Version 20231A minor electrical permit label may not be used for an installation ________. All of the statements are correct For a swimming pool That requires a plan review That requires a sheet rock cover inspection Reference : 918-309-0220(3) 3. 135 – Oregon Rule and Law Version 20231Temporary electrical work permits can be used for ________. Unanticipated electrical work Any provisional work in hazardous locations only And by homeowners Small installations so that no electrical permit is needed also Reference : 918-309-0075(2) 4. 093 – Oregon Rule and Law Version 20231The 2023 NEC additionally required barriers to cover the exposed energized bussing for feeder panelboards. The Oregon Electrical Specialty Codes ________. Did not adopt these changes Additionally requires warning labels Additionally requires taping the terminals Only recommends this requirement Reference : Table 1-E 215.15 5. 094 – Oregon Rule and Law Version 20231The 2023 NEC required that a low voltage residential lighting switch not exclusively rely on batteries unless the lights would automatically energize if the batteries failed. The State of Oregon Rules ________. Do not require this change Clarify that this is only a recommendation Additionally requires posting labels at the panelboard Does not now allow these low voltage switches Reference : Table 1-E 210.70 6. 026 – Oregon Rule and Law Version 20231In Oregon State, ________ in a dwelling unit are not required to have GFCI protection for all 125 volt, single phase, 15-20 ampere receptacles Kitchen receptacles that do not serve the countertop Laundry areas Garages Outdoors Reference : Table 1-E , 210.8(A)(6) 7. 022 – Oregon Rule and Law Version 20231A dormitory in Oregon is considered a space in a building where group sleeping accommodations are provided in one or more closely associated rooms with up to _________ persons There is no designated count 12 16 10 Reference : Table 1-E, 100 8. 020 – Oregon Rule and Law Version 20231Existing electrical installations in Oregon that complied with previous National Electrical Code standards Are considered presently in violation of current codes if the use of the building is changed Are considered presently in violation of current codes May be considered in violation of current codes in all cases Will never be considered in violation of current codes Reference : 918-305-0000 9. 140 – Oregon Rule and Law Version 20231When notification to a jurisdiction of the use of a temporary electrical permit is called in, the original with payment must also be mailed in within ________. 7 days 6 days 5 days 4 days Reference : 918-309-0080(4) 10. 041 – Oregon Rule and Law Version 20231Conduits or raceways through which moisture may contact live parts shall be sealed At either or both ends At one end only At both ends With identified listed sealant for use Reference : Table 1-E, 300.5(G) 11. 064 – Oregon Rule and Law Version 20231When an electrical contractor has a person that is Continuously Employed, he or she devotes ________ of employment to the tasks such as supervising. Their entire time 0.5 0.25 0.75 Reference : 918-251-0090 12. 046 – Oregon Rule and Law Version 20231If electrical equipment has been damaged by fire or water, it shall be evaluated by _______ prior to being returned to service. The signing supervisor A licensed journey-level electrician A qualified testing laboratory only The manufacturer only Reference : Table 1-E , 408.9(B) 13. 095 – Oregon Rule and Law Version 20231Additional surge protection for feeders was a major change in the NEC. The State of Oregon ________. Does not require this Only requires this for dormitory units Only requires this for guest rooms in a hotel Only requires this for dwelling units Reference : Table 1-E 215.18 14. 089 – Oregon Rule and Law Version 20231The 2023 NEC added additional GFCI protection requirements for aquariums and bait wells. The Oregon rules modified with an exception if the device is installed ________ and a single receptacle is installed. Indoors Outdoors Above 5 feet Above 6 feet Reference : Table 1-E 210.8(B)ex7 15. 143 – Oregon Rule and Law Version 20231A master electrical work permit is used by industrial plants and governmental entities. A master permit is ________. An annual permit Valid for 6 months before expiration Valid for another year after the last inspection Remains active until canceled Reference : 918-309-0100(2) 16. 159 – Oregon Rule and Law Version 20231The misuse and violations of minor installation label rules ________. Are subject to civil penalties Shall result in civil penalties not to exceed 250 dollars Shall result in a license suspension Shall result in a license revocation Reference : 918-309-0260 17. 003 – Oregon Rule and Law Version 20231Return of the minor label log sheet to the division or proper jurisdiction shall be: when all the labels in the lot are used, or ________ from the date of sale; whichever occurs first 12 months 6 months 9 months 90 day Reference : 918-100-0050 18. 154 – Oregon Rule and Law Version 20231A limited energy contractor can use a limited minor electrical permit for ________. Audio and stereo systems Any vacuum system not over 5 Security systems but only under 5 Fire alarms Reference : 918-309-0220(6) 19. 030 – Oregon Rule and Law Version 20231A 125 volt, 20 ampere receptacle, installed inside a dwelling unit to service heating and air conditioning equipment is Not required to be GFCI protected unless required otherwise in the code Required to be GFCI protected Required to be installed within 60 feet of the unit Required to be installed with AFCI protection Reference : Table 1-E , 210.8(E) 20. 076 – Oregon Rule and Law Version 20231A general journey-level can be exempt from the engineering requirements for the designing of a fire protection system. When he/she qualifies, he/she is not subject to any requirements for additional ________. Permits Certification stamps Training Installation requirements Reference : 918-261-0015 (2) 21. 158 – Oregon Rule and Law Version 20231 A properly licensed electrical contractor may use a minor label permit for an altered electrical service that does not exceed ________ provided it is not required to be reconnected by the serving utility. 200 amps and 150 volts to ground 200 amps and 250 volts to ground 400 amps and 150 volts to ground 400 amps and 250 volts to ground Reference : 918-309-0220(7) 22. 055 – Oregon Rule and Law Version 20231Feeders and Branch Circuits that supply power and installed on docking facilities Do not require GFCE protection if modifying an existing system Do not require GFCE protection Requires GFCI protection of 4-6 milliamperes Requires GFCI protection of 30 milliamperes Reference : Table 1-E , 555.35(A) 23. 001 – Oregon Rule and Law Version 20231An electrical minor label is chosen to permit a small job. When must you post the label on the job site? Before the work begins After the work is completed Within 10 calendar days of completion Before or while the work is in progress Reference : 918-100-0050 24. 160 – Oregon Rule and Law Version 20231Renewable Electrical Energy Bulk Labels may be purchased by ________. A general contractor The property owner only A limited renewable energy contractor only Any licensed electrician Reference : 918-309-0410(1) 25. 120 – Oregon Rule and Law Version 20231The Oregon Electrical Specialty Code does not require an electrical work permit for ________. Some minor electrical installations that can use a minor installation label Homeowners C.O.P. locations Any low voltage applications Reference : 918-309-000(10) 26. 130 – Oregon Rule and Law Version 20231Bulk electrical permit labels are sold ________ at $25.00 per label Only to electrical contractors To anyone needing a permit To homeowners and low voltage electrical contractors Only to homeowners Reference : 918-309-0040(9) 27. 053 – Oregon Rule and Law Version 20231Ground-fault protection performance testing in a Health Care Facility shall be conducted by A person with proper training to evaluate the results A qualified person The manufacturer only A licensed journey-level electrician Reference : Table 1-E , 517.17(D) 28. 088 – Oregon Rule and Law Version 20231The 2023 NEC defines a kitchen which includes an area with sinks and permanent provisions for food preparation. Th Oregon State rules Did not adopt this definition Expanded the definitions to outside wet bars Expanded the definition to include beverage preparation Have adopted the 2023 NEC definition Reference : Table 1-E 210.8(A) 29. 101 – Oregon Rule and Law Version 20231The Oregon State Electrical Specialty Code amendments now allow Electrical Nonmetallic Tubing in buildings exceeding three floors above grad ________. If installed in accordance with Standard NFPA13 In commercial applications only When identified at the source panelboard Reference : Table 1-E 362.10 30. 005 – Oregon Rule and Law Version 20231Electrical licenses in Oregon are not required to do testing of electrical products in _________. All of these statements are true. A recognized UL testing lab Industrial plants An electrical shop Reference : 918-282-0110 31. 071 – Oregon Rule and Law Version 20231When an electrical item is Labeled, it will have an identifying mark by ________. An NRTL UL only CSA or UL only ETL only Reference : 918-251-0090 32. 156 – Oregon Rule and Law Version 20231A properly licensed electrical contractor may use a minor label permit for a circuit extension of not more than ________ electrical circuits limited to 60 amps and not more than 150 volts to ground. 3 2 1 4 Reference : 918-309-0220(7) 33. 149 – Oregon Rule and Law Version 20231 A minor permit label in Oregon is an alternative option for smaller installations instead of a standard electrical permit. A minor label may be used for ________. Underground electrical installations Any circuit extension Burglar or security alarms Hot water heaters Reference : 918-309-0220(3) 34. 113 – Oregon Rule and Law Version 20231An electrical work permit shall be posted ________. In a conspicuous place near the panel or on the job site Near the main electrical panel In the electrical room On the main electrical panel Reference : 918-309-000(4) 35. 011 – Oregon Rule and Law Version 20231A limited supervising electrician may direct an electrical installation in an existing _________. Hospital Duplex Dwelling Unit Multifamily structure Reference : 918-282-0160 36. 104 – Oregon Rule and Law Version 20231An electrical Oregon Rule and Law states that panelboards where the available fault current is greater than ________, the panelboard and enclosure shall be evaluated to verify it can withstand the fault. The State of Oregon does not require this evaluation 40 20 10 Reference : Table 1-E 408.38 ____ 37. 016 – Oregon Rule and Law Version 20231A licensed journey-level limited sign electrician is not permitted to Perform work on service equipment Install outline lighting Extend any sign circuit Install electrical signs Reference : 918-282-0220 38. 079 – Oregon Rule and Law Version 20231An example of the exemption for underground electrical transmission lines from permits and licensing is when the equipment is owned and operated by ________. A municipality A hospital A county A school Reference : 918-261-0030 39. 146 – Oregon Rule and Law Version 20231A covered facility can obtain and use a master electrical permit only if ________. Licensed electricians do the work The facility has used these permits before The facility is over 10 They agree to have progress inspections once a month Reference : 918-309-0100(5) 40. 132 – Oregon Rule and Law Version 20231A stop-work order may only be issued for ________ violations of the minimum electrical safety standards. Permitted projects for Commercial only for Major Homeowner projects for Reference : 918-309-0075(2) 41. 060 – Oregon Rule and Law Version 20231For a Natural and Artificially Made Body of Water, outlets supplied by branch circuits not exceeding ________ single phase, shall be provided with GFCI protection for personnel 60 amperes 30 amperes 20 amperes The State of Oregon has not adopted this NEC section Reference : Table 1-E , 682.2(A) 42. 103 – Oregon Rule and Law Version 20231A new general 2023 rules does not allow receptacle outlets within 3 feet of a dwelling unit bathtub or shower. A modified exception for a small bathroom in Oregon allows the receptacle to be installed ________. Outside the room To be eliminated On the farthest wall within the room Next to the toilet Reference : Table 1-E 406.9(C) 43. 049 – Oregon Rule and Law Version 20231Need to be specifically approved by a supervisor Now all of these are required in Oregon Shall meet the requirements of 445.19(A)(1) Shall be located outside Shall be accessible Reference : Table 1-E , 445.19(C) 44. 019 – Oregon Rule and Law Version 20231A general journey-level electrical 8,000 hour apprenticeship program in Oregon with at least ________ hours of on-the-job training may work under indirect supervision. 6500 6000 5000 7000 Reference : 918-282-0270 45. 083 – Oregon Rule and Law Version 20231A change in the definition of servicing in the Oregon rules now includes the ________ of used equipment with listed or recognized components. (Also can be a factor when it comes to licensing compliance.) All of these items are now included Repair Testing Inspection Reference : Table 1-E 100 Definitions 46. 151 – Oregon Rule and Law Version 20231A limited maintenance specialty HVAC/R contractor may use a minor electrical permit label if the single phase installation does not exceed ________. 150 volts to ground 208 volts to ground 240 volts to ground 250 volts to ground Reference : 918-309-0220(5) 47. 107 – Oregon Rule and Law Version 20231Ground-Fault Circuit-Interrupter Protection (GFCI) for personnel was modified in the NEC to cover all receptacles for electric hand tools or portable lighting in work areas for welders. The Oregon amendments ________. Did not adopt this code section Requires GFCI protection for both 120 volt and 250 volt receptacles Only require GFCI protection for 250 volt receptacles Only require GFCI protection for 120 volt receptacles Reference : Table 1-E 630.8 48. 111 – Oregon Rule and Law Version 20231When purchasing an electrical permit for the State of Oregon, the signature of ________ is required on each permit. A signing supervising electrician The site owner The building owner The electrical contractor Reference : 918-309-000(1) 49. 062 – Oregon Rule and Law Version 20231The definition of Appliance, in regards to the limited maintenance specialty contractor license, does not include Generally Deep frying equipment Clothes washing equipment Food mixing equipment Reference : 918-251-0090 50. 002 – Oregon Rule and Law Version 20231Minor labels sold by the division for electrical installations shall be sold ___________. In lots of 10 In lots of 20 In lots of 50 One at a time Reference : 918-100-0030 Back Save Progress Retry Finish