Oregon Rule and Law Version 2023 Quiz Please sign up for the before taking this quiz. Back Save Progress Retry Finish 1. 003 – Oregon Rule and Law Version 20231Return of the minor label log sheet to the division or proper jurisdiction shall be: when all the labels in the lot are used, or ________ from the date of sale; whichever occurs first 12 months 6 months 9 months 90 day Reference : 918-100-0050 2. 084 – Oregon Rule and Law Version 20231The 2023 NEC has now begun to address cybersecurity for network-connected life safety equipment. In Oregon the permit holder ________ demonstrate compliance with this requirement for this type of installation. Is not required to Shall not Is recommended to Is required to Reference : Table 1-E 110.3(A)(8) 3. 011 – Oregon Rule and Law Version 20231A limited supervising electrician may direct an electrical installation in an existing _________. Hospital Duplex Dwelling Unit Multifamily structure Reference : 918-282-0160 4. 035 – Oregon Rule and Law Version 20231In a dormitory unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in Bathrooms Closets Hallways Living rooms Reference : Table 1-E , 210.12(C) 5. 133 – Oregon Rule and Law Version 20231The Oregon Electrical Specialty Code allows ________ to purchase and use temporary electrical work permits. Licensed electrical contractors only General contractors for construction temporaries Any supervisor electrician Any technician Reference : 918-309-0080(1) 6. 019 – Oregon Rule and Law Version 20231A general journey-level electrical 8,000 hour apprenticeship program in Oregon with at least ________ hours of on-the-job training may work under indirect supervision. 6500 6000 5000 7000 Reference : 918-282-0270 7. 033 – Oregon Rule and Law Version 20231In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in Locations with dedicated outlets that supply equipment known to cause unwanted tripping All of these statements are true Sunrooms with GFCI protection Living rooms with dedicated circuits Reference : Table 1-E , 210.12(B) ex 3 8. 094 – Oregon Rule and Law Version 20231The 2023 NEC required that a low voltage residential lighting switch not exclusively rely on batteries unless the lights would automatically energize if the batteries failed. The State of Oregon Rules ________. Do not require this change Clarify that this is only a recommendation Additionally requires posting labels at the panelboard Does not now allow these low voltage switches Reference : Table 1-E 210.70 9. 064 – Oregon Rule and Law Version 20231When an electrical contractor has a person that is Continuously Employed, he or she devotes ________ of employment to the tasks such as supervising. Their entire time 0.5 0.25 0.75 Reference : 918-251-0090 10. 049 – Oregon Rule and Law Version 20231Need to be specifically approved by a supervisor Now all of these are required in Oregon Shall meet the requirements of 445.19(A)(1) Shall be located outside Shall be accessible Reference : Table 1-E , 445.19(C) 11. 072 – Oregon Rule and Law Version 20231A Limited Energy System can mean a system that includes ________. All of these statements are true. An audio system A power limited fire alarm A communication system Reference : 918-251-0090 12. 083 – Oregon Rule and Law Version 20231A change in the definition of servicing in the Oregon rules now includes the ________ of used equipment with listed or recognized components. (Also can be a factor when it comes to licensing compliance.) All of these items are now included Repair Testing Inspection Reference : Table 1-E 100 Definitions 13. 103 – Oregon Rule and Law Version 20231A new general 2023 rules does not allow receptacle outlets within 3 feet of a dwelling unit bathtub or shower. A modified exception for a small bathroom in Oregon allows the receptacle to be installed ________. Outside the room To be eliminated On the farthest wall within the room Next to the toilet Reference : Table 1-E 406.9(C) 14. 101 – Oregon Rule and Law Version 20231The Oregon State Electrical Specialty Code amendments now allow Electrical Nonmetallic Tubing in buildings exceeding three floors above grad ________. If installed in accordance with Standard NFPA13 In commercial applications only When identified at the source panelboard Reference : Table 1-E 362.10 15. 147 – Oregon Rule and Law Version 20231When an electrical contractor using a master permit for a facility ceases to cover that location, the inspecting jurisdiction shall be notified by the permit holder within ________ of the termination. 10 days 5 days 14 days 30 days Reference : 918-309-0100(6) 16. 082 – Oregon Rule and Law Version 20231A new clarification of the NEC definition of a structure in Oregon now includes ________. (Important when it comes to floating a neutral or not.) A post with an attached meter base An electric pump station A branch circuit to a furnace Any light standard Reference : Table 1-E 100 Definitions 17. 150 – Oregon Rule and Law Version 20231A minor electrical permit label may not be used for an installation ________. All of the statements are correct For a swimming pool That requires a plan review That requires a sheet rock cover inspection Reference : 918-309-0220(3) 18. 008 – Oregon Rule and Law Version 20231When a general supervising electrician is working for an electrical contractor, he/she may design, plan, and lay out work for ________. The customers of the contractor he/she is working for Any installation within his/her electrical scope Any installation if he/she is an engineer Only for altered electrical services Reference : 918-282-0140 19. 151 – Oregon Rule and Law Version 20231A limited maintenance specialty HVAC/R contractor may use a minor electrical permit label if the single phase installation does not exceed ________. 150 volts to ground 208 volts to ground 240 volts to ground 250 volts to ground Reference : 918-309-0220(5) 20. 118 – Oregon Rule and Law Version 20231When corrections have been issued to a permitted electrical installation, those corrections must be completed within ________ of the notification. 20 days 15 days 30 days 60 days with extensions Reference : 918-309-000(8) 21. 037 – Oregon Rule and Law Version 20231A deck or porch that is located above grade is required to have at least 1 receptacle outlet installed, unless It has a depth of 1 foot or less It has a depth of 2 feet or less It has an area of less than 25 square feet It has an area of less than 30 square feet Reference : Table 1-E , 210.52(E)(3) 22. 048 – Oregon Rule and Law Version 20231Stationary generators 600 volts and less Are not required to be listed Shall be listed Shall be identified only Need to be specifically approved by a supervisor Reference : Table 1-E , 445.6 23. 128 – Oregon Rule and Law Version 20231The electrical work permit fee for a manufactured dwelling unit (mobile home) ________. Is typically based on a service and feeder fee Is based on square footage Has a discount available for senior citizens Has a discount available for multiple units Reference : 918-309-0030(5) 24. 119 – Oregon Rule and Law Version 20231The Oregon Electrical Specialty Code does not require any type of an electrical work permit for Replacing fuses Changing luminaire ballasts Changing luminaire drivers Replacing receptacles and switches Reference : 918-309-000(10) 25. 135 – Oregon Rule and Law Version 20231Temporary electrical work permits can be used for ________. Unanticipated electrical work Any provisional work in hazardous locations only And by homeowners Small installations so that no electrical permit is needed also Reference : 918-309-0075(2) 26. 127 – Oregon Rule and Law Version 20231To calculate the fee for an electrical work permit for a one-family dwelling, ________. You must include the square footage of the garage if it is attached The attached garage is not included in this footprint A discount is available for senior citizens The Specialty Code does not clarify fees regarding garages Reference : 918-309-0030(5) 27. 086 – Oregon Rule and Law Version 20231A new alterative method from the 2023 NEC to recondition and restore electrical equipment in Oregon is to use replacement parts ________. Selected by the supervising electrician Designed by any engineer By the manufacturer only Selected by the electrical inspector Reference : Table 1-E 110.20 28. 123 – Oregon Rule and Law Version 20231When an electrical contractor has a job that requires a state plan review process, _________. A partial permit may be purchased so work can begin An outside firm can be hired to complete the review They can only begin with express consent from the chief They can not begin any work until the process is completed Reference : 918-309-0025(1) 29. 089 – Oregon Rule and Law Version 20231The 2023 NEC added additional GFCI protection requirements for aquariums and bait wells. The Oregon rules modified with an exception if the device is installed ________ and a single receptacle is installed. Indoors Outdoors Above 5 feet Above 6 feet Reference : Table 1-E 210.8(B)ex7 30. 034 – Oregon Rule and Law Version 20231In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in An area that serves an appliance that is fastened in place A pet wash location An area that could be considered a damp location that can cause unwanted tripping In any wet location Reference : Table 1-E , 210.12(B)ex 4 31. 129 – Oregon Rule and Law Version 20231When an electrical service was disconnected for repairs, if a major violation of the service exists, ________. A new service and permit fee is required The corrections shall be completed with 30 days A citation shall be issued to the owner A citation shall be issued to the electrical contractor Reference : 918-309-0040(9) 32. 112 – Oregon Rule and Law Version 20231In the State of Oregon, an electrical work permit is required ________. Prior to the start of the electrical work Before an inspection request Within 1 day of the start of the work Before the plan review process Reference : 918-309-000(3) 33. 153 – Oregon Rule and Law Version 20231A limited maintenance specialty contractor can take advantage of a minor label electrical permit to replace up to ________ ballasts for light fixtures under one minor permit. 10 15 12 20 Reference : 918-309-0220(5) 34. 154 – Oregon Rule and Law Version 20231A limited energy contractor can use a limited minor electrical permit for ________. Audio and stereo systems Any vacuum system not over 5 Security systems but only under 5 Fire alarms Reference : 918-309-0220(6) 35. 146 – Oregon Rule and Law Version 20231A covered facility can obtain and use a master electrical permit only if ________. Licensed electricians do the work The facility has used these permits before The facility is over 10 They agree to have progress inspections once a month Reference : 918-309-0100(5) 36. 090 – Oregon Rule and Law Version 20231The 2023 NEC expanded the requirements for GFCI protection for appliances, the Oregon Specialty Code clarified GFCI protection for _________. Specific appliances 3 phase appliances only Single phase appliances only No appliances Reference : Table 1-E210.8(D) 37. 004 – Oregon Rule and Law Version 20231A registered signing supervising electrician shall provide direct supervision or control on a job by ________. All of these statements are true. Being on the job site Having a continuously employed full time supervising electrician on the job site Be available in person to meet with the inspector on the job site within 2 business days Reference : 918-282-0015 38. 140 – Oregon Rule and Law Version 20231When notification to a jurisdiction of the use of a temporary electrical permit is called in, the original with payment must also be mailed in within ________. 7 days 6 days 5 days 4 days Reference : 918-309-0080(4) 39. 012 – Oregon Rule and Law Version 20231A licensed general journey-level electrician is authorized to do ________. Any electrical installation Residential electrical installations only General electrical installations only Commercial electrical installations only Reference : 918-282-0170 40. 100 – Oregon Rule and Law Version 20231The Oregon State Electrical Specialty amendments allow overcurrent protective devices in ________. Locker rooms Hotel guest room bathroom Dormitory unit bathrooms Dwelling unit bathrooms Reference : Table 1-E 240.24(E) 41. 005 – Oregon Rule and Law Version 20231Electrical licenses in Oregon are not required to do testing of electrical products in _________. All of these statements are true. A recognized UL testing lab Industrial plants An electrical shop Reference : 918-282-0110 42. 108 – Oregon Rule and Law Version 20231In an emergency system such as egress lighting, if the transfer switch is supplied by a single feeder, additional redundant transfer equipment is required by the NEC that is available so maintenance and repairs can take place. The Oregon amendments only require this if ________. The building owner deems it necessary The plan review requires it It is a public school It is a hospital Reference : Table 1-E 700.5 43. 052 – Oregon Rule and Law Version 20231Part II of NEC Article 517 shall not apply to ________ areas. All of these statements are true Audiology Physical therapy Message therapy Reference : Table 1-E , 517.10(B) 44. 152 – Oregon Rule and Law Version 20231A limited maintenance specialty contractor may use a minor electrical permit label for ________. A garbage disposal up to 20 amperes A dishwasher up to 30 amperes A fan up to 25 amperes A furnace up to 30 amperes Reference : 918-309-0220(5) 45. 092 – Oregon Rule and Law Version 20231The Oregon State rules also modified the 2023 NEC arc fault requirements for dormitory unit receptacles by additionally adding ________ areas. Study Outside Lobbies Parking Reference : Table 1-E 210.12(C) 46. 032 – Oregon Rule and Law Version 20231In a dwelling unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in All of these statements are true Hallways Laundry areas Kitchens Reference : Table 1-E , 210.12(B)ex 2 47. 080 – Oregon Rule and Law Version 20231An example of a condition requirement for product use in a system that generates and distributes electricity that is not certified includes the ________. System being designed by an engineer Owner not being a wholesale generator System is not connected to a utility grid Turbines are 10KW Reference : 918-261-0030 48. 115 – Oregon Rule and Law Version 20231An unexpired permit holder ________ for an extension of time within which work may be completed. May apply Of a residential project only may apply Of a commercial project only may apply May not apply Reference : 918-309-000(6) 49. 107 – Oregon Rule and Law Version 20231Ground-Fault Circuit-Interrupter Protection (GFCI) for personnel was modified in the NEC to cover all receptacles for electric hand tools or portable lighting in work areas for welders. The Oregon amendments ________. Did not adopt this code section Requires GFCI protection for both 120 volt and 250 volt receptacles Only require GFCI protection for 250 volt receptacles Only require GFCI protection for 120 volt receptacles Reference : Table 1-E 630.8 50. 044 – Oregon Rule and Law Version 20231Receptacles shall not be installed within or above a bathtub, Or shower stall Or steam room Nor within 12 feet vertically Nor within 5 feet horizontally Reference : Table 1-E , 406.9(C) Back Save Progress Retry Finish