2026 Changes Part 1- OR Quiz Please sign up for the before taking this quiz. Back Save Progress Retry Finish 1. 200 – 2026 Changes Part 11Service equipment is permitted to be installed in or on a manufactured home only if which condition is met? It is installed in a bedroom closet It is installed by the utility It is mounted on the roof All NEC conditions for location Reference:550.51 B 1-7 2. 95 – 2026 Changes Part 11Intermediate Metal Conduit (IMC) is permitted in areas subject to even severe corrosive influences provided they are protected by corrosion protection approved for the condition such as _______. (Some of these locations include agricultural with fertilizer exposure, wastewater facilities, coastal areas with salt environments, and industrial sites.) Adding caution tape Sealing the raceway Coating the raceway Using galvanized steel Reference:342.10 B 3. 47 – 2026 Changes Part 11The NEC essential general requirements for grounding and bonding have been restructured to provide a clear list format, restating clearly that the earth shall not be ________. (Previously this section was in one single dense paragraph. This formatting change should be helpful to all stakeholders.) Used for dissipation of surges Used for a voltage reference Considered a ground-fault path Used for dissipation of lightning Reference:250.4 A5 4. 79 – 2026 Changes Part 11A new section now clearly states that _________ cannot be reconditioned and installed. (Seems to come up more frequently now as our electrical equipment ages and natural disasters occur.) All electrical equipment Fittings Meter socket enclosures Electrical mechanical supports Reference:312.3 5. 165 – 2026 Changes Part 11All underground wiring in aircraft hangars shall comply with 513.8(A), 513.8(B), or 513.8(C). Where such wiring is located in vaults, pits, or ducts, adequate drainage shall be provided and the installation shall comply with the requirements for __________ locations.(This revised text removes the requirement to classify underground installation At aircraft hangers solely as Class one, Division one ) Class I Unclassified Class II Reference:513.8 6. 121 – 2026 Changes Part 11A new NEC revision adds requirements for identification and labeling of switchboards, switchgear, and panelboards. Under this revision, which section must these assemblies comply with? Section 408.3 Support and arrangement of busbars Section 90.7 Examination of equipment for safety Section 250.8 Equipment grounding conductor identification 110.21 B Identification of disconnecting means Reference:408.10 F 7. 169 – 2026 Changes Part 11Additional sources of electrical service permitted to supplement the utility service in healthcare facilities shall have the capacity and rating to meet the maximum actual demand likely to be produced by the connected load. Demand calculations for sizing these systems shall be based on one or more of the following EXCEPT __________. Feeder calculations Connected loads Prudent demand factors and historic data The nameplate rating of the largest single piece of equipment only Reference:517.4 B 8. 1 – 2026 Changes Part 11A new list item now permits grounded neutral conductors sized 6 AWG and smaller with white or gray insulation to have a ________. (This should help match a neutral to the corresponding phase conductors in a raceway with other conductors. ( This has already been done in other countries.) Double stripe Color painted on Single colored stripe other than green Green colored stripe Reference:200.7 A 9. 3 – 2026 Changes Part 11Ground-Fault Circuit-Interrupter Protection (GFCI) requirements in dwelling units have made adjustments to include storage and work areas not intended as habitable rooms ______________. This modification is intended to decrease hazards. Regardless of grade level Only that have a floor located at grade level Only that have a floor located below grade level Only that have a floor located at grade or below grade level Reference:210.8 A 10. 65 – 2026 Changes Part 11The NEC created Article 270 to cover grounding and bonding for systems over 1000 volts AC or 1500 volts DC. Grounding for systems _________ is now also covered. (These systems can be specialized with increased risk of ground touch potential.) That supply portable or mobile equipment Over 500 volts AC For utilities Over 500 volts DC Reference:270.20 C 11. 155 – 2026 Changes Part 11Which of the following bonding methods is not permitted for normally noncurrent?carrying metal parts in hazardous classified locations?(Vision grounding and bonding requirements for hazardous locations were found in three different locations ) Listed bonding bushings with bonding jumpers Locknuts Tight threadless couplings used with metal raceways Threaded couplings made up wrench?tight Reference:500.30 B 12. 149 – 2026 Changes Part 11Which of the following correctly describes the requirements for grounding switches used in medium? and high?voltage equipment?(This new section brings clarity and structure to the application by mandating key safeguards that help prevent accidental energization or unsafe switching sequences ) Grounding switches are required to be load?break rated and may be used as the primary disconnecting means Grounding switches only need to be interlocked with the service disconnect Grounding switches may be operated at any time as long as the operator is wearing appropriate PPE Grounding switches must be interlocked with all disconnecting means so the disconnects are open before grounding Reference:495.26 13. 53 – 2026 Changes Part 11The NEC requirement to provide an Intersystem Bonding Termination (IBT) device at the service equipment and separate structure now additionally able to be secured and connect directly to ___________. (ITBs are used as a common grounding point for other systems like telephone, cable, and broadband. These are frequently grounded improperly if at all.) A minimum 6 AWG copper grounding electrode conductor Any location inside A satellite electrode A non-metallic enclosure Reference:250.94 A 14. 69 – 2026 Changes Part 11Generally, wiring methods and materials installed under ________ has been revised and still must maintain a separation of no less than 1 1/2 inch from the roof decking. (This section was also re-written in the 2023 NEC.) All types of roof decking A metal-corrugated roof decking only A plywood-type roof decking only Any wood decking only Reference:300.6 E 15. 133 – 2026 Changes Part 11Heat strips installed inside HVAC enclosures shall be________. (This change was prompted by the sale and widespread reports of supply houses selling heat strips not for specific applications compromising the listing of the entire unit ) Purchased from the manufacturer of the HVAC unit being worked on Listed as a field installable accessory None of these answers are correct Inspected by the AHJ (Authority having jurisdiction ) Reference:440.2 16. 192 – 2026 Changes Part 11Where must the equipment grounding conductor (EGC) be connected for a separately derived system such as a generator? (Stated an article 525 exception it reads this section 525.31 shall not apply to portable generators used in accordance with 445.20 A exception ) At any convenient point in the portable structure At the load terminals of the transfer switch Only at the service disconnect At the generator or the first disconnecting means supplied by the generator Reference:525.31 17. 67 – 2026 Changes Part 11A new NEC section identifies conductors that are considered damaged and now would require replacement including _________. (This damage can compromise insulation ratings and cause short circuits.) Severe cold Water damage Aged over 50 years Smoke damage Reference:300.4 C 18. 158 – 2026 Changes Part 11In Class I, Division 1 locations, one or more of the wiring methods in__________ shall be used in accordance with the requirements of the sections in the reference column and with the respective wiring?method requirements applied. For example, Type P cable is permitted only in __________ industrial establishments.(This update puts the code into table form for improve usability enabling installers to more clearly determine which wiring methods are allowed ) table 501.10 A 1. & Restricted Ordinary Temporary Commercial Reference:501.1 19. 38 – 2026 Changes Part 11The NEC code section that governs the maximum number of disconnects each service can have (the two to six rule) has also been updated regarding how the disconnects can be physically arranged including _____________. (To also address maintenance safety and arc-flash protection.) Interrupting capacity Locations Arc-Flash ratings Switchboards Reference:230.71 B 20. 37 – 2026 Changes Part 11The NEC section that governs the maximum number of disconnects each service can have has been revised and clarifies that ______ does not have to be counted as one of the permitted service disconnects. (There was confusion about disconnects that served as protection rather than load-serving functions.) A switchboard The disconnection of surge-protection devices Service disconnects rated under 30 amperes A metering center Reference:230.71 A 21. 105 – 2026 Changes Part 11Article 404 requires switches to be installed in easily accessible locations. What is the maximum permitted height to the center of the grip of the operating handle when the switch is in its highest position? 6 ft 0 in 5 ft 6 in 6 ft 7 in 7 ft 0 in Reference:404.10 A 2 22. 111 – 2026 Changes Part 11In the 2026 NEC, the new code section for wiring devices is reorganized into how many distinct parts? (The new layout breaks the material into **three clearly separated parts**, making it easier to distinguish: – **Wiring?devicetype switches** – **Receptacles and cord connectors** – **Attachment plugs (caps)** ) 3 5 4 2 Reference:406 23. 72 – 2026 Changes Part 11A new option item ________ was added to address areas where raceways were subject to temperature changes that can cause condensation. (The circulation of warm area such as into a cold storage is the primary cause of condensation in raceways that can then drip into electrical enclosures.) Entry height Marking requirement Listed fittings Conduit length Reference:300.9 A 24. 129 – 2026 Changes Part 11Fixed outdoor electric deicing and snow?melting equipment includes which of the following? . Only roof?mounted heating cables Conductive pavement heating systems Only factory?assembled heating systems Only embedded concrete heating mats Reference:Article 424, 425, 426 and 427 25. 63 – 2026 Changes Part 11New NEC Article 268 covers services over 1000 volts AC or 1500 volts DC and acknowledges that supervised installations can have grounding and bonding designed by _______. (A formal introduction of customized conductor sizing for high voltage systems.) A local utility company A qualified person The authority having jurisdiction (AHJ) The National Electrical Code tables only Reference:268.42 C 26. 139 – 2026 Changes Part 11According to the 2026 NEC the terminology for generator remote emergency shutdown has been modernized by replacing an old term emergency stop switch with_______. (This update reflects the evolution of generator control technologies which increasingly rely on digital systems programmable interfaces and network control circuits rather than physical traditional switches ) Emergency disconnect Generator lockout switch Shutdown device Remote trip mechanism Reference:445.19 B 27. 11 – 2026 Changes Part 11Branch-circuit disconnecting means rated 1000 amperes or more, solidly grounded, but not exceeding ____ volts line to line now mandates GFCI protection even for DC systems. (The NEC is trying to keep up with the increased usage of DC power such as in data centers, EV charging, energy storage systems, and large scale solar.) 2000 2400 2500 1500 Reference:210.13 A&B 28. 96 – 2026 Changes Part 11For Intermediate Metal Conduit (IMC) __________ now permitted as an acceptable means to prevent galvanic corrosion when joining dissimilar metals. (This comes up in retrofits such as industrial expansions or changes.) All listed fittings are Identified bimetallic couplings Bonding jumpers made of brass Bonding jumpers made of copper or brass Reference:342.14 29. 152 – 2026 Changes Part 11According to the 2026 NEC clarification to 500.5(D)(1), Class III, Division 1 locations include which of the following?( This adjustment brings greater clarity to the user especially in areas involving dust and fiber hazard classifications in industrial environments ) Any location containing Class I or Class II materials Only locations where ignitable fibers are manufactured Those locations specifically identified in 500.5(D)(1)(a) through 500.5(D)(1)© Only locations where combustible dusts are present in suspension Reference:500.5 30. 144 – 2026 Changes Part 11According to 2026 NEC which of the following must be grounded in stationary battery installations?(This update clarifies outdated text by adding clear requirements That are very actionable :All conductive battery rack stands cabinets and cases must be grounded) Conductive battery stands Only battery enclosures located outdoors Only battery chargers associated with the system nly metallic battery terminals Reference:480.8 31. 156 – 2026 Changes Part 11Which of the following statements correctly reflects the revised requirements for reconditioned equipment used in hazardous (classified) locations? Only equipment located outside the hazardous location requires reconditioning evaluation Reconditioned equipment is prohibited in all hazardous locations unless field?evaluated by the AHJ Reconditioned equipment is permitted All reconditioned equipment must be listed and marked Explosion?Proof regardless of original classification Reference:501.3 32. 7 – 2026 Changes Part 11As a general rule, in dwelling units, outdoor circuits rated at 150 volts or less to ground require GFCI protection for __________. (This increase addresses the trend for larger HVAC units now being installed in residential applications.) 80 amperes or less 70 amperes or less 60 amperes or less 100 amperes or less Reference:210.8 F 33. 6 – 2026 Changes Part 11An exception for Ground-Fault Circuit-Interrupter Protection (GFCI) requirements for an industrial establishment requires _________. (The electrical industry has been complaining about overapplication of GFCI requirements; this revision reflects that.) Equipment design not compatible with GFCI protection These are all requirements for a GFCI exception. As Assured Equipment Grounding Conductor Program (AEGCP) Supervision and only qualified personnel Reference:210.8 B ex 2 34. 39 – 2026 Changes Part 11The list that governs what equipment is allowed to be used on the supply side (line side) of service equipment has undergone a substantial re-organization and now also includes _________. (This reflects the increased demand for these to enhance safety also during maintenance.) Listed smoke detection systems Video monitoring systems AVTs (absence of voltage testers) Type 3 surge-protection devices Reference:230.82 35. 170 – 2026 Changes Part 11All activities, systems, and equipment that are new or altered in patient care spaces shall be designed and installed to meet the requirements of which of the following?(NFPA 99 category 1 failure likely to cause major injury or death category two failure could cause minor injury category three failure unlikely to cause injury but may cause discomfort category 4 failure has no impact on safety or care ) Only Category 3 and Category 4 spaces Only the category assigned by the authority having jurisdiction Only Category 1 and Category 2 spaces Category 1 through Category 4 requirements NFPA 99 health care faculties code chapter 4 Reference:517.7 & Informational note 36. 57 – 2026 Changes Part 11New Article 265 now specifically covers branch circuits over 1000 volts AC and 1500 volts DC but also additionally recommends _________ for additional information. (Content relocation from Article 235 to restructure low-voltage (LV) and medium voltage (MV) systems.) Article 250 Article 266 The National Electrical Safety Code United Laboratories (UL) Reference:265.1 37. 51 – 2026 Changes Part 11In an enhancement to the grounding and bonding rules the NEC has added ________ to the list of raceways that shall be bonded at both ends if it contains a grounding electrode conductor. (Nonferrous metals like aluminum do not produce significant magnetic properties or heat so do not create the same risk during a fault condition.) All raceways Nonferrous metal enclosures All metallic raceways Ferrous metal cable armor raceways Reference:250.64 E1 38. 18 – 2026 Changes Part 11A change in determining the required receptacle outlet placement in dwelling units was a revision to exclude _________ from the wall space measurements. (The purpose was to reduce the overuse of extension cords. This should simplify the task of laying out receptacle outlet locations in the home.) Only fixed cabinets with countertops Any fixed cabinet Only fixed cabinets that are not recessed Only fixed cabinets with a work surface Reference:210.52 A2(1) 39. 172 – 2026 Changes Part 11Part II of Article 517 does NOT apply to which of the following spaces? Patient sleeping rooms in nursing homes wired under Chapters 14 and used exclusively for sleeping Category 1 treatment rooms used for invasive procedures Patient care areas used for direct preparation and care Imaging suites used for diagnostic procedures Reference:517.10 B 40. 184 – 2026 Changes Part 11Overcurrent protective devices serving the Essential Electrical System (EES) must be coordinated for the period of time that a faults duration extends beyond which of the following?(The addition of subsection F is a critical enhancement to the National Electric Code in 2026 as it addresses the need for precise coordination of over current protective devices in EES ‘s. This author thinks precise coordination is needed in all applications, who wants a main fuse blowing or circuit breaker turning off everything that you are addressing in whichever system you’re addressing? Life safety of course is more urgent ) 0.05 second 0.1 second 0.01 second 1.0 second Reference:517.42 F 41. 23 – 2026 Changes Part 11Automatic controls like motion sensors or time based controllers ________ as the sole means of controlling illumination in attics, underfloor spaces, and utility rooms. (To ensure that we are not left stranded in the dark in a potentially dangerous tight space.) are permitted if a warning label is also provided are not permitted unless with a manual bypass are allowed are never allowed Reference:210.70 C3 42. 196 – 2026 Changes Part 11The construction of an equipotential plane shall comply with which NEC subsections?(This change introduces new detailed construction requirements for a quick potential planes in agricultural buildings ) 110.26(A)(1) through (A)(3) 547.44(C)(1) through 547.44(C)(4) 300.5(A) through (A)(4) 250.8(A)(1) through (A)(6) Reference:547.44 C 43. 60 – 2026 Changes Part 11For branch circuits over 1000 volts AC that can require servicing, a 125 volt single phase 15- or 20-ampere receptacle outlet shall be available __________. (Generally the receptacle shall not be powered from the load side of the equipment.) Unless the system is in an isolated area Unless the system is outdoors Within the same room or area Unless the system is supervised Reference:265.63 B 44. 114 – 2026 Changes Part 11On work surfaces, receptacles shall not be installed in a face?up position unless which condition is met? The receptacle is part of a listed assembly specifically designed for face?up installation The receptacle is located more than 12 inches from a sink and AFCI Reference:406.14 G 45. 167 – 2026 Changes Part 11Each dispensing device shall be provided with a means to remove all external voltage sources during maintenance and service. This disconnecting means shall remove ungrounded and grounded power conductors, communication, data, and video circuits. The location of this means is permitted to be __________. . Only inside the dispensing device Inside Only adjacent to the dispensing device Other than inside or adjacent to the dispensing device Reference:514.13 46. 116 – 2026 Changes Part 11Which of the following is required for a faceplate that incorporates a night light and is installed over a receptacle outlet? It shall be listed as a combination faceplate assembly It shall be supplied only by a Class 2 power source only It shall be installed only in dwelling-unit bedrooms It shall be a blank faceplate with no openings Reference:406.16 D 47. 142 – 2026 Changes Part 11According to 2026 NEC which of the following statements correctly describes the rules for installing reconditioned reactors and resistors? Neither reconditioned reactors nor reconditioned resistors are permitted to be installed . Reconditioned resistors are permitted to be installed Reconditioned reactors are permitted to be installed Both reconditioned reactors and reconditioned resistors are permitted to be installed Reference:470.3 A B 48. 2 – 2026 Changes Part 11New Article 206 outlines the general requirements for ________. (Non-Powered-Limited circuits can pose a bigger risk for fire and shock. Previously this content was limited to Chapter 3.) Power-Limited Remote-Control Circuits Non-Powered-Limited Signaling circuits Overvoltage protection All circuits under 100 volts Reference:206.1 49. 12 – 2026 Changes Part 11___________ that include cooking facilities which have permanent provisions for cooking shall now meet the kitchen small applicance branch circuit AFCI and GFCI requirements of dwelling units. (Previously only guest rooms and suites in hotels or motels were required.) Industrial and commercial break rooms Holding tanks Dormitories (16 individuals or more) Commercial break rooms Reference:210.17 50. 66 – 2026 Changes Part 11A revision to Chapter 3 also now clearly shows what is not covered and includes ________ (to give a clear explanation and framework for compliance and installation.) Conductors not over 1500 Volts DC Conductors not over 1000 Volts AC Conductors to services Class 4 circuits Reference:300.1 51. 138 – 2026 Changes Part 11According to 2026 NEC when a generator set is equipped with a listed overcurrent protective device or a combination of a current transformer and overcurrent relay, conductors are permitted to be tapped from the load side of the protected terminals under which condition? Only if the tap conductors comply with 240.21(B) Only if the tap conductors are supervised by an AHJ?approved maintenance program Only if the tap conductors are less than 10 ft in length Only if the tap conductors are installed in rigid metal conduit Reference:445.13 B 52. 109 – 2026 Changes Part 11According to the NEC, which of the following statements about reconditioned wiring devices is correct?(Wiring devices cannot be reconditioned because they’re inexpensive are safety critical have internal components that cannot be inspected and are not designed for refurbishment ) Reconditioned wiring devices are permitted if listed by a third?party refurbisher Reconditioned wiring devices are permitted only in non?dwelling occupancies Reconditioned wiring devices are permitted if tested by a qualified person Reconditioned wiring devices are not permitted to be used Reference:406.3 53. 119 – 2026 Changes Part 11According to the NEC, which of the following types of equipment is not permitted to be reconditioned? Panelboards . Switchboards Switchgear Motor control centers Reference:408,3 B 54. 58 – 2026 Changes Part 11The NEC created a new code section for branch circuits over 1000 volts AC that allows conductor sizing to be determined by other than the NEC tables if the installation is __________. (This acknowledges that these can be complicated systems requiring flexibility.) Located outdoors Based on temperature rise Provided under engineering supervision In a campus environment Reference:265.19 B 55. 132 – 2026 Changes Part 11Motor control centers supplied by a feeder shall be marked in accordance with which section to identify the location of all means necessary to disconnect power to the motor control center? 408.4 Circuit directory and identification 430.102 Disconnecting means for motors 110.16 Arc?flash hazard warning 110.21(B) Field?applied hazard markings Reference:430.98 A 56. 30 – 2026 Changes Part 11Service equipment beyond what is specified in 230.2 A shall be _______. (With the changing times, service equipment may need to be modified or custom-built in the field.) Field evaluated only Listed as suitable for service only Listed or field evaluated Additionally certified Reference:230.2 B 57. 166 – 2026 Changes Part 11Emergency electrical disconnects for fuel?dispensing systems shall be installed in approved locations not less than 20 ft and not more than 100 ft from the dispensing devices they serve. Activation of the emergency shutoff device or electrical disconnect shall disconnect power to all of the following EXCEPT __________.(Just change Clarifies receptacles over or adjacent to motor fuel and dispensing devices and hazardous classified locations must be disconnected during an emergency ) Intrinsically safe electrical equipment All remote pumps serving the dispensing devices . All dispensing devices not supplied by intrinsically safe circuits All associated power Reference:514.11 A 58. 8 – 2026 Changes Part 11For a dwelling unit outdoor outlet replacement for listed HVAC equipment, _____________. (This should help this industry with unwanted tripping because standard GFCIs were incompatible.) Listed Class C SPGFCI protection is permitted instead of GFCI GFCI protection is only suggested now. There are no longer exceptions; it shall be GFCI protected. Assured Grounding Reference:210.8 F ex 3 59. 90 – 2026 Changes Part 11Nonmetallic-Sheathed Cable (Types NM and NMC, Romex) now requires listed products such as _______ be used during installation. (One of the most widely used wiring methods can be damaged by sharp edges or improper sizing.) Staples Straps only 2 hole straps only Hangers only Reference:334.2 60. 162 – 2026 Changes Part 11Cannabis extraction operations shall NOT be located in any building containing which of the following occupancies? Mercantile occupancies only Industrial or storage occupancies only Business occupancies only Assembly Reference:512.6 61. 147 – 2026 Changes Part 11According to 2026 enclosures installed in damp or wet locations must be weatherproof. For enclosures in wet locations, raceways or cables entering above the level of uninsulated live parts must use fittings listed for which type of location?(Previously in section 495.3 These requirements are now clearly presented under section 495.4 with a specific title allowing designers, installers and inspectors to identify the applicable rules for damp and what locations easily) Corrosive locations only Wet locations Hazardous (Class I Indoor dry locations only Reference:495.4 62. 146 – 2026 Changes Part 11According to the 2026 NEC which of the following correctly describes the new listing requirements and effective dates for high?voltage switchgear and industrial control assemblies? All equipment over 1 Equipment rated not over 15 Only equipment over 52 Reference:495.2 AB 63. 164 – 2026 Changes Part 11According to the 2026 NEC, reconditioned equipment permitted to be installed in Zone?classified locations shall comply with the requirements of __________. . 500.8 only 501.3 and 505.3 501.10(A)(1) only Article 430 Part IV Reference:513.3 A 64. 91 – 2026 Changes Part 11A new exception allows nonhabitable grade level storage buildings less than _______ with Type V construction to use NM cable without a 15-minute thermal barrier. A 15-minute thermal barrier typically is a gypsum wallboard (sheetrock) covering. 2000 square feet 1750 square feet 1500 square feet 2400 square feet Reference:334.1 65. 126 – 2026 Changes Part 11Fixed storage type water heaters 120 gallons or less are now classified as ? (Finally, clarity sometimes we need that ) As cold water heaters Classification was removed Continuous load Continuous load only for branch circuit conductors Reference:422.13 66. 50 – 2026 Changes Part 11A building service with multiple disconnecting means in separate enclosures is allowed to use a common grounding electrode, with a tap to each disconnect __________. (The format also changed from a dense paragraph to the list-style because of common misapplications and inconsistent interpretations.) As permitted by" the AHJ Only if the common electrode terminates in one of the enclosures As permitted by" a licensed electrical engineer When installed "in accordance with" the technical NEC requirements Reference:250.64 D1 67. 85 – 2026 Changes Part 11New listing requirements for Metal-Clad Cable (Type MC) now requires ________ to be listed and identified for use. (Based on the UL standard 2239 for safety of hardware.) The cable only The brackets Staples and/or straps The fittings only Reference:330.2 68. 82 – 2026 Changes Part 11Restoring and reconditioning Medium Voltage (MV 2,000 to 35,000 Volts AC) electrical equipment for re-use such as _________ is now prohibited. (MV equipment is very vulnerable to degradation. Restoring has become popular to cut costs.) Rejuvenation Cable removal Cable relocation Cable terminations Reference:315.3 69. 168 – 2026 Changes Part 11In addition to the off?site utility electrical service, which of the following sources are permitted to supplement the service and supply the entire electrical load of a healthcare facility, based on reliability?(This is great for electrical services and healthcare faculties allowing alternative and distributed energy systems such as microgids fuel cells and energy storage systems to legally supplement electrical supply this enables healthcare systems to improve reliability and energy independence beyond traditional utilities ) Only generators listed for emergency systems Only energy storage systems listed for standby use Photovoltaic systems only Power production sources Reference:517.4 70. 176 – 2026 Changes Part 11A sign must be placed at the service?entrance equipment indicating the type and location of each on?site power source. Which of the following is exempt from this signage requirement? Energy storage systems . Battery?equipped emergency luminaires Battery?equipped emergency luminaires Reference:517.28 A ex. 71. 70 – 2026 Changes Part 11The requirement to maintain a 1 1/2 inch spacing from a roof decking for cables, raceways, and boxes now includes a decking poured with light weight concrete at least ______. (It is common during roofing repairs or replacement to use long screws that can penetrate wiring methods.) 1 inch thick 1 3/4 inch thick 2 inches thick 1 1/2 inch thick Reference:300.6 E 72. 89 – 2026 Changes Part 11The NEC has eliminated ________ as an option for securing Mineral-Insulated (Type MI) cable. (Type MI cable is often used for fire alarms, high temperature locations, and emergency systems. It can be vulnerable to mechanical stresses during the installation.) Staples Hangers Straps Straps and hangers Reference:332.3 73. 154 – 2026 Changes Part 11The 2026 NEC requires which of the following bonding methods for normally noncurrent?carrying metal parts of electrical equipment, raceways, metal?clad cable, and metal enclosures in hazardous classified locations? Threaded couplings/hubs made up wrench?tight Any mechanical connection Bonding is not required if the system voltage is under 50 volts Only wire?type equipment grounding conductors installed in every raceway Reference:500.3 74. 124 – 2026 Changes Part 11The NEC requires central heating equipment to be supplied by an individual branch circuit. Exception No. 1 has been expanded to include which additional type of equipment? Electric baseboard heaters Wall?mounted room air conditioners Ductless mini?split systems Similar equipment Reference:422.12 ex.#1 75. 175 – 2026 Changes Part 11According to the 2026 NEC, the requirements of Article 700 shall NOT apply to which of the following?(This change addresses the impracticality of applying article 700 to all components of the electrical essentials system the change emphasizes only life safety branch of the essential electrical system must comply with 700 ) Emergency lighting systems in non?healthcare buildings Legally required standby systems Essential electrical systems in healthcare facilities Optional standby systems Reference:517.26 76. 22 – 2026 Changes Part 11When a laundry area is located inside a closet or compact enclosure, both the lighting outlet and the control device _________. (To reflect common small laundry rooms such as in multifamily applications.) shall be located inside the laundry area adjacent to the door can now be located outside of the laundry area must be located outside of the laundry area shall be marked at the switch Reference:210.70 A ex 3 77. 42 – 2026 Changes Part 11A new code section for overcurrent protection now covers and introduces the new term “transformer secondary conductors,” and they are permitted to be ________. (This change separates feeder tap conductor from the transformer secondary rules.) Considered protected without overcurrent protection Considered protected without overcurrent protection at the secondary Always installed without protection regardless of length Tapped without restrictions Reference:240.21 B3 and 240.21 C 78. 131 – 2026 Changes Part 11Reconditioned motors are permitted to be installed only if the reconditioning has been performed in accordance with which of the following? The reconditioning contractors documented quality?control program The installers field evaluation or local AHJ preference The manufacturers instructions The motor nameplate data and conductor ampacity tables Reference:430.3 79. 19 – 2026 Changes Part 11The residential installation of receptacle outlets on the walls of cabinets with countertops or work surfaces shall now be installed no less than _______ below that countertop. (Recent code cycles restricted the number and locations because of the large number of inuries to crumb crunchers as a result of pulling the appliance cords. Kitchen appliance cords are 2 feet long.) 24 inches 6 inches 12 inches 18 inches Reference:210.52 A5 80. 123 – 2026 Changes Part 11The NEC restructuring of horticultural lighting into Sections (A) and (B) is based on which voltage threshold? 150 volts to ground 300 volts to ground 120 volts to ground 50 volts to ground Reference:410.184 A B 81. 107 – 2026 Changes Part 11Knife switches used for isolating rated less than ______ shall be considered general?use switches. 1200 amps at 250 volts or less and at over 1000 amps at 251 to 1000 volts 1000 amps at 250 volts or less and at over 1000 amps at 251 to 1000 volts 750 amps at 750 volts all these answers are true Reference:404.13 C 82. 87 – 2026 Changes Part 11A new list item added as an approved method for supporting and securing Metal-Clad Cable (Type MC) is _________. (Designed to restrain cables from whipping during a fault condition which can cause damage.) Jacketing Cable cleats Blocking Any hangers Reference:330.30 A 83. 41 – 2026 Changes Part 11A new section in NEC article 240 identifies what overcurrent protective devices (OCPDs) are suitable and approved for providing branch-circuit, feeder service conductors and electrical equipment including _________. (The intent was to create one location for users that identified the types of breakers and fuses that the NEC recognized.) Class C fuses Class A fuses Class B fuses Class A Reference:240.7 84. 197 – 2026 Changes Part 11Which of the following best describes the updated GFCI requirement for receptacle outlets in Article 550?(Instead of specifying certain appliances and locations in a mobile or manufactured home the language Changed to reference section 210.8 This completely removes any differences between the old mobile home requirements And stick built home requirements ) GFCI protection is optional if the receptacle is within sight of the panelboard GFCI protection must be provided as required in 210.8 Only outdoor receptacles require GFCI protection Receptacle outlets must be GFCI?protected only when installed in bathrooms Reference:550.13 B 85. 34 – 2026 Changes Part 11There are now enhanced marking requirements for one- and two-family residential service disconnects and specifically state that the marking ______. (Some state rules also have additional requirements.) Must have a red text Letters shall be at least 1/2 inch high Must have a black background Shall be located adjacent to the disconnect Reference:230.70 B2 86. 117 – 2026 Changes Part 11Tamper?resistant receptacle requirements have expanded to include which of the following locations in addition to dwelling units? Parks and recreation Commercial garages Health care patient rooms Assembly occupancies Reference:406.26 87. 160 – 2026 Changes Part 11According to the NEC, electrical equipment and wiring for electric vehicle power transfer systems shall be installed in accordance with Article 625 Part III, except as modified by 511.10(B)(2) and 511.10(B)(3). Flexible cords used in these systems shall be __________. Permitted only when installed in rigid metal conduit Limited to a maximum length of 3 ft Identified for extra?hard usage Suitable for damp locations only Reference:511.10 B 88. 103 – 2026 Changes Part 11When using reconditioned switches, not all types are permitted to be installed. Which type is permitted under the 2026 National Electrical Code? Dimmer switches General?use snap switches GFCI?type switching devices Knife switches Reference:404.3 89. 17 – 2026 Changes Part 11If a 14 AWG Copper-Clad Aluminum Conductor is used to supply a branch circuit, the maximum overcurrent protection (circuit breaker) device rating is ___________. (This major change is the NEC response and solution to lower power usage. Copper-Clad seems lighter and more flexible to use but more subjectable to damage. This circuit is not allowed to supply receptacle outlets.) 12 amperes 15 amperes 8 amperes 10 amperes Reference:Table 210.24(2) 90. 28 – 2026 Changes Part 11The NEC section requiring emergency disconnects for feeders to structures for one- and two-family dwellings was revised for clarity. The disconnect can be installed on the structure or within sight which is now _______ in this situation . (There were proposals to allow the emergency disconnects to be installed with an unlimited distance.) 100 feet 75 feet 50 feet 60 feet Reference:225.41 A1 91. 127 – 2026 Changes Part 11Conductive pavement heating systems shall be designed as which of the following? Site?specific engineered designs by both civil and electrical engineers Field?assembled systems supervised by the installer shall have a plan review Standard off?the?shelf listed assemblies Reference:426.64 92. 157 – 2026 Changes Part 11Section 501.3(B) of the 2026 NEC is ____________. Reserved for future use A new requirement for intrinsically safe systems A requirement for wiring methods in Class I A prohibition on reconditioned equipment in hazardous locations Reference:501.3 B 93. 113 – 2026 Changes Part 11Non grounding type receptacles with no grounding conductor present can be replaced with_______. Grounding type receptacles AFCI receptacles All of these answers are false 20 amp grounding type receptacles Reference:406.12 D 1 94. 74 – 2026 Changes Part 11When cable ties are used as support for flexible conduit and tubing they shall be listed and identified for that purpose such as ________. (The 2023 edition of the NEC officially allowed the use of cable ties for cable systems.) Type 25 or 21 S Type 11 Type 2C or 11C Type 21C Reference:300.13 E 95. 102 – 2026 Changes Part 11A significant change to NEC Article 404 in the 2026 edition is: (The 2026 NEC narrows Article 404 to cover only equipment?type switches. Device?type switchessuch as snap switches, dimmers, and electronic controlswere moved to Article 406 as part of a structural reorganization.) The elimination of Article 404 and redistribution of its content into Chapter 2 The relocation of most device?type switches The increase of allowable switch voltage ratings to 2000 volts The expansion of Article 404 to include all wiring devices such as receptacles and GFCIs Reference:404.1 B 96. 195 – 2026 Changes Part 11Which of the following is REQUIRED for bonding an equipotential plane under NEC 547?(This change makes it clear and enforceable standard for constructing equipped potential planes in agricultural environments ) It must be connected only to the service neutral It must be bonded with a #12 copper conductor to any nearby metal object It must be bonded to the grounding electrode system or an equipment grounding terminal using a solid copper conductor not smaller than #8 AWG It may be bonded with aluminum conductors if not subject to corrosion Reference:547.44 B 97. 98 – 2026 Changes Part 11A revised section for cable trays now requires a minimum space of ________ above the cable tray for access unless an exception is met. (In many commercial, industrial, and data centers these trays can become very congested.) 10 inches 12 inches 6 inches 18 inches Reference:392.18 F 98. 128 – 2026 Changes Part 11The NEC requirement for listing in Article 424 has been expanded in the 2026 edition to include which of the following? Baseboard heater raceways Electric baseboard heaters Unit heater fan motors Embedded snow?melting mats Reference:424.2 99. 83 – 2026 Changes Part 11Armored Cable is now required to be supported with approved and listed _________. (Non listed devices can degrade with time under heat.) Hangers only Staples Straps only 2 hole straps only Reference:320.2 100. 182 – 2026 Changes Part 11Essential electrical system (EES) loads must be served by two or more independent sources or sets of power sources and feeders. At least one of these sources must be __________, and additional sources are permitted to be __________. Off?site; off?site only On?site but sized only for the life?safety branch; on?site only On?site and sized to supply the entire EES; either on?site or off?site Off?site and sized to supply the entire EES; on?site only Reference:517.41 A Complete Quiz Restart Quiz Save Progress Back Save Progress Retry Finish