Test Quiz Please sign up for the before taking this quiz. Back Save Progress Retry Finish 1. 081 – Oregon Rule and Law Version 20231In a new change to the Oregon amendments to the 2023 NEC, there now includes a clarification for the electrical datum plane (elevation) calculations for locations such as marinas. The electrical datum plane shall be determined in accordance with __________ codes. The Oregon Structural or Residential codes An electrical supervisor Each county jurisdiction The NEC 2020 edition Reference : Table 1-E 90.4(D) 2. 017 – Oregon Rule and Law Version 20231A licensed limited stage electrician journey-level Can maintain temporary equipment used during a show when it is designed to be accessed by qualified personnel Can install permanent wiring at a performance venue Cannot work on film or video productions Does not have to be employed by an electrical contractor when working Reference : 918-282-0230 3. 116 – Oregon Rule and Law Version 20231Electrical work permits issued under the Oregon Specialty Code become null and void if the electrical work is not started within ________. 180 days 120 days 60 days 365 days Reference : 918-309-000(7) 4. 150 – Oregon Rule and Law Version 20231A minor electrical permit label may not be used for an installation ________. All of the statements are correct For a swimming pool That requires a plan review That requires a sheet rock cover inspection Reference : 918-309-0220(3) 5. 045 – Oregon Rule and Law Version 20231In the State of Oregon, all 15 and 20 ampere, 125 volt, nonlocking type receptacles in _________ shall be listed as tamper-resistant receptacles Mobile homes Outdoor locations All locations Business offices Reference : Table 1-E , 406.12 6. 035 – Oregon Rule and Law Version 20231In a dormitory unit, AFCI protection shall not be required for 120 volt, single phase, 15 and 20 ampere branch circuits supplying receptacles located in Bathrooms Closets Hallways Living rooms Reference : Table 1-E , 210.12(C) 7. 009 – Oregon Rule and Law Version 20231________ is the only individual authorized to supervise the installation or alteration of an electrical service A general supervising electrician A general electrician A journey-level electrician The owner Reference : 918-282-0140 8. 123 – Oregon Rule and Law Version 20231When an electrical contractor has a job that requires a state plan review process, _________. A partial permit may be purchased so work can begin An outside firm can be hired to complete the review They can only begin with express consent from the chief They can not begin any work until the process is completed Reference : 918-309-0025(1) 9. 156 – Oregon Rule and Law Version 20231A properly licensed electrical contractor may use a minor label permit for a circuit extension of not more than ________ electrical circuits limited to 60 amps and not more than 150 volts to ground. 3 2 1 4 Reference : 918-309-0220(7) 10. 148 – Oregon Rule and Law Version 20231Records required when a master annual permit is used also include ________. The license number of the person doing the work The materials list used to complete the alteration Any anticipated future projects A one line diagram of the changes Reference : 918-309-0100(6) 11. 129 – Oregon Rule and Law Version 20231When an electrical service was disconnected for repairs, if a major violation of the service exists, ________. A new service and permit fee is required The corrections shall be completed with 30 days A citation shall be issued to the owner A citation shall be issued to the electrical contractor Reference : 918-309-0040(9) 12. 027 – Oregon Rule and Law Version 20231Indoor damp and wet locations of dwelling units are ________ GFCI protection for 125 volt, 15 and 20 ampere receptacles. Are no longer mentioned in the ORLs Now recommended to have Suggested to install Required to have (starting 1/1/25) Reference : Table 1-E , 210.8(A) 13. 054 – Oregon Rule and Law Version 20231In a place of assembly, illumination shall be required for working spaces around outdoor None of these statements are true. Switchgear Service equipment only Motor control centers Reference : Table 1-E , 518.6 14. 155 – Oregon Rule and Law Version 20231Generally, a limited energy contractor can use a limited minor electrical permit for a new installation of up to ________ in new construction. 10 devices 15 devices 20 devices 25 devices Reference : 918-309-0220(6) 15. 103 – Oregon Rule and Law Version 20231A new general 2023 rules does not allow receptacle outlets within 3 feet of a dwelling unit bathtub or shower. A modified exception for a small bathroom in Oregon allows the receptacle to be installed ________. Outside the room To be eliminated On the farthest wall within the room Next to the toilet Reference : Table 1-E 406.9(C) 16. 070 – Oregon Rule and Law Version 20231In Oregon, a Jurisdictional Inspector can be a ________. State or municipal inspector Municipal inspector only State inspector only County inspector only Reference : 918-251-0090 17. 128 – Oregon Rule and Law Version 20231The electrical work permit fee for a manufactured dwelling unit (mobile home) ________. Is typically based on a service and feeder fee Is based on square footage Has a discount available for senior citizens Has a discount available for multiple units Reference : 918-309-0030(5) 18. 092 – Oregon Rule and Law Version 20231The Oregon State rules also modified the 2023 NEC arc fault requirements for dormitory unit receptacles by additionally adding ________ areas. Study Outside Lobbies Parking Reference : Table 1-E 210.12(C) 19. 149 – Oregon Rule and Law Version 20231 A minor permit label in Oregon is an alternative option for smaller installations instead of a standard electrical permit. A minor label may be used for ________. Underground electrical installations Any circuit extension Burglar or security alarms Hot water heaters Reference : 918-309-0220(3) 20. 036 – Oregon Rule and Law Version 20231Receptacle outlets shall be installed for a dwelling unit kitchen island At least 1 At least 2 One minimum at each end At least 1 for the first 9 square feet Reference : Table 1-E , 210.52(C)(2) Complete Quiz Restart Quiz Save Progress Back Save Progress Retry Finish